Caterpillar 3516E-3250 Diesel Generator Set
CAT 3516E-3250 Diesel Generator Sets is a V-4-Cylinders 78.1 Liter ( 4764.73 in³ ) Displacement Engine with 170.0 mm (6.69 in.) Bore and 215.0 mm (8.46 in.) Stroke.
Equipped with Dual Caterpillar® A3 Electronic Control Unit (ECU) LH with Electronic Unit Injector Fuel System Rigid Wiring Harness and ADEM™ A5 Governor.The Prime Power for 50 Hz Generator Set (1500 RPM) of CAT 3516E-3250 Diesel Generator Sets is 2950 kVA (2360 ekW) and a Standby Power of 3250 kVA (2600 ekW).
CAT 3516E-3250 Diesel Genset Powered by CAT Diesel Engine with EMCP 4 Control Panel, Diesel Genset with Turbocharged & Water-Air Intercooler.
CAT Diesel Generator Sets Meet Tier III / Tier IV Emission Standards.
Our Diesel Generator Set Series Includes High Power Medium and High Voltage Generator Sets and High Power Low Voltage Generator Sets. The Engine Provides Electronically Controlled and Mechanical Fuel Injection Systems for Customers to Choose. In Addition to Generating Diesel Generator Sets, We Can Also Supply Marine Diesel, Oil, Gas, Marine Generator Sets.
We Provide Full Life Cycle Services for All Customers, From Design to Power System Supply, From Installation to Commissioning, From After-Sales Service Training to Spare Parts Supply, From Troubleshooting to Overhaul Technical Support.
Advantages of EQB125-20 Automotive Engine
High power generation efficiency: The power generation efficiency of CAT Caterpillar gas-fired internal combustion generator sets is about 33 – 41 %, and the efficiency of combined heat, power and cooling can reach more than 80 %.
Low requirements for gas source: The gas internal combustion generator set has low requirements on the intake pressure (medium and low pressure) and intake temperature of the gas source, and has a wide range of calorific value.
Wide range of power used: Caterpillar gas internal combustion generator sets have a power range of 80 to 3480 kW, which can operate as a single unit or in parallel with multiple units, grid-connected operation, and flexible station construction.
Wide range of adaptation to ambient temperature and altitude. At an ambient temperature of 40 degrees Celsius and an altitude of 500 meters, the rated power of the Caterpillar gas-fired internal combustion generator set is not compromised, and it can output 100 %.
Technical Specifications
Basic Introduction of Cat 3516E-3250 Diesel Generator Sets
Genset Model: | 3516E-3250 |
Prime Power: | 2360 kW @ 1500 RPM |
Genset Frequency: | 50 Hz |
Engine Model: | 3516 |
Standby: | 2600 kW / 3250 kVA |
Bore: | 170 mm |
Stroke: | 215mm |
Displacement: | 78.1 L |
Dry Weight: | 20380 kg |
Lead Time: | 15-30 Working Days |
Payment Terms: | T/T ,L/C |
Engine Model | Standby | Prime | Aspiration | Fuel System |
3516-2000 | 2000 kVA / 1600 ekW | 1825 kVA / 1460 ekW | Turbocharged & Water-Air Intercooler | MUI |
3516B-2250 | 2250 kVA / 1800 ekW | 2000 kVA / 1600 ekW | Turbocharged & Water-Air Intercooler | MUI |
3516B-2500 | 2500 kVA / 2000 ekW | 2275 kVA / 1820 ekW | Turbocharged & Water-Air Intercooler | MUI |
3516C-2750 | 2750 kVA / 2200 ekW | 2500 kVA / 2000 ekW | Turbocharged & Water-Air Intercooler | MUI |
3516E-3000 | 3000 kVA / 2400 ekW | 2750 kVA / 2200 ekW | Turbocharged & Water-Air Intercooler | MUI |
3516E-3250 | 3250 kVA / 2600 ekW | 2950 kVA / 2360 ekW | Turbocharged & Water-Air Intercooler | MUI |
3516E-3500 | 3500 kVA / 2800 ekW | 3175 kVA / 2540 ekW | Turbocharged & Water-Air Intercooler | MUI |
——END—— |
General Information of CAT 3516E-3250 Diesel Generator Set | |||
Engine Model | 3516E-3250 | Displacement | 78.1 L / 4764.73 in³ |
Compress Ratio | 14.0 : 1 | Bore | 170 mm / 6.69 in |
Fuel System | EUI | Stroke | 215 mm / 8.46 in |
Aspiration | TA | Standby | 3250 kVA / 2600 ekW |
Frequency | 50 Hz | Prime | 2950 kVA / 2360 ekW |
Length | 7685 mm / 302.6 in | Mission Critical | 3250 kVA / 2600 ekW |
Width | 2612 mm / 102.8 | Height | 3342 mm / 131.6 in |
Emissions Performance | Optimized For Low Fuel Consumption | Governor Type | ADEM™ A5 |
Dry Weight | 20380 kg / 44930 Ib | ||
——END—— |
Package Performance of CAT 3516E-3250 Diesel Generator Set | ||||
Standby | Mission Critical | Prime | ||
Performance | Frequency — Hz | 50 | 50 | 50 |
Gen Set Power Rating with Fan — ekW | 2600 | 2600 | 2360 | |
Gen Set Power Rating with Fan @ 0.8 Power Factor — kVA | 3250 | 3250 | 2950 | |
Emissions | Tier 2 (EPA Emergency) | Tier 2 (EPA Emergency) | Tier 2 (EPA Emergency) | |
Performance Number | EM4773-04 | EM4779-01 | EM4785-01 | |
Fuel Consumption | 100% Load With Fan — L/hr (gal/hr) | 706.2 / 186.6 | 706.2 / 186.6 | 656.8 / 173.5 |
75% Load With Fan — L/hr (gal/hr) | 562.6 / 148.6 | 562.6 / 148.6 | 519.8 / 137.5 | |
50% Load With Fan — L/hr (gal/hr) | 381.1 / 100.7 | 381.1 / 100.7 | 351.3 / 92.8 | |
25% Load With Fan — L/hr (gal/hr) | 215.9 / 57.0 | 215.9 / 57.0 | 201.1 / 53.1 | |
Cooling System | Radiator Air Flow Restriction — kPa (in.water) | 0.12 / 0.48 | 0.12 / 0.48 | 0.12 / 0.48 |
Radiator Air Flow — m³/min (cfm) | 2878 / 101635 | 2878 / 101635 | 2878 / 101635 | |
Engine Coolant Capacity — L (gal) | 179.0 / 47.3 | 179.0 / 47.3 | 179.0 / 47.3 | |
Radiator Coolant Capacity — L (gal) | 202.0 / 53.4 | 202.0 / 53.4 | 202.0 / 53.4 | |
Total Coolant Capacity — L (gal) | 381.0 / 100.7 | 381.0 / 100.7 | 381.0 / 100.7 | |
Inlet Air | Combustion Air Inlet Flow Rate — m³/min (cfm) | 212.5 / 7502.5 | 212.5 / 7502.5 | 176.8 / 7155.0 |
Exhaust System | Exhaust Stack Gas Temperature — °C (°F) | 495.0 / 922.9 | 495.0 / 922.9 | 495.0 / 923.4 |
Exhaust Gas Flow Rate — m³/min (cfm) | 578.0 / 20408.1 | 578.0 / 20408.1 | 549.3 / 19395.4 | |
Exhaust System Backpressure — kPa (in. Water) | 7.0 / 28.1 | 7.0 / 28.1 | 7.0 / 28.1 | |
Heat Rejection | Heat Rejection To Jacket Water — kW (Btu/min) | 880 / 50024 | 880 / 50024 | 822 / 46767 |
Heat Rejection To Exhaust (Total) —kW (Btu/min) | 2766 / 157294 | 2766 / 157294 | 2635 / 149839 | |
Heat Rejection To Aftercooler — kW (Btu/min) | 817 / 46478 | 817 / 46478 | 741 / 42144 | |
Heat Rejection To Atmosphere From Engine — kW (Btu/min) | 168 / 9556 | 158 / 9556 | 165 / 9395 | |
Heat Rejection From Alternator — kW (Btu/min) | 113 / 6426 | 113 / 6426 | 88 / 5010 | |
Emissions* (Nominal) | NOX — mg/Nm³ (g/HP-h) | 2176.4 / 4.68 | 2176.4 / 4.68 | 1839.1 / 4.03 |
CO — mg/Nm³ (g/HP-h) | 265.8 / 0.57 | 265.8 / 0.57 | 319.3 / 0.70 | |
HC — mg/Nm³ (g/HP-h) | 12.4 / 0.03 | 12.4 / 0.03 | 12.9 / 0.03 | |
PM — mg/Nm³ (g/HP-h) | 11.5 / 0.03 | 11.5 / 0.03 | 15.7 / 0.04 | |
Emissions* (Potential Site Variation) | NOX — mg/Nm³ (g/HP-h) | 2611.7 / 5.62 | 2611.7 / 5.62 | 2207.0 / 4.83 |
CO — mg/Nm³ (g/HP-h) | 478.4 / 1.03 | 478.4 / 1.03 | 574.8 / 1.27 | |
HC — mg/Nm³ (g/HP-h) | 16.5 / 0.04 | 16.5 / 0.04 | 17.1 / 0.04 | |
PM — mg/Nm³ (g/HP-h) | 16.1 / 0.04 | 16.1 / 0.04 | 22.0 / 0.06 | |
——END—— |
Ratings Definitions of CAT 3516E-3250 Diesel Generator Set | |||
Standby | 1. Output Available With Varying Load For The Duration Of The Interruption Of The Normal Source Power. Average Power Outputis 70% Of The Standby Power Rating Typical Operation Is 200 Hours Per Year, With Maximum Expected Usage Of 500 Hours Per Year | Prime | 1. Output Available With Varying Load For An Unlimited Time. Average Power Output Is 70% Of The Prime Power Rating. Typical Peak Demand Is 100% Of Prime Rated Ekw With 10% Overload Capability For Emergency Use For A Maximum Of 1 Hour In 12. Overload Operation Cannot Exceed 25 Hours Per Year |
Fuel Rates | 1. Fuel Rates Are Based On Fuel Oil Of 35º Api [16°C (60ºf)] Gravity Having An Lhv Of 42,780 Kj/Kg (18,390 Btu/Lb) When Used At 29ºc (85ºf) And Weighing 838.9 G/Liter (7.001 Lbs/U.S. Gal.) | Applicable Codes and Standards | 1. As 1359, Csa C22.2 No. 100-04, Ul 142, Ul 489,Ul 869, Ul 2200, Nfpa 37, Nfpa 70, Nfpa 99, Nfpa 110, Ibc, Iec 60034-1, Iso 3046, Iso 8528, Nema Mg1-22, Nema Mg1-33, 2014/35/Eu, 2006/42/Ec, 2014/30/Eu |
Data Center Applications | 1. Lso 8528-1 Data Center Power (Dcp) Compliant Per Dcp Application Of Cat Diesel Generator Set Prime Power Rating | ||
2. All Ratings Tier Iii/Tier Iv Compliant Per Uptime Institute Requirements | |||
3. All Ratings Ansi/Tia-942 Compliant For Rated-1 Through Rated-4 Data Centers | |||
——END—— |
Optional Equipment of CAT 3516E-3250 Diesel Generator Set | |||||
Engine | Air Cleaner | Power Termination | Type | Alternator | Output Voltage |
1. Single Element | 1. Bus Bar | 1. 380 V | |||
2. Dual Element | 2. Circuit Breaker | 2. 400 V | |||
3. Heavy Duty | 3. 1250 A | 3. 415 V | |||
Muffler | 4. 1600 A | Temperature Rise(Over 40°C Ambient) | |||
1. Industrial Grade (10 Db) | 5. 2500 A | 1. 125 °C | |||
Starting | 6. 3-Pole | 2. 105 °C | |||
1. Standard Batteries | 7. Iec | 3. 3.08 °C | |||
2. Oversized Batteries | 8. Manually Operated | Winding Type | |||
3. Heavy Duty Electric Starter(S) | 9. Electrically Operated | 1. Random Wound | |||
4. Dual Electric Starter(S) | Trip Unit | Excitation | |||
5. Jacket Water Heater | 1. Lsi | 1. Self Excited | |||
6. N/A | 2. N/A | 2. Permanent Magnet (Pm) | |||
Control System | Controller | Extended Service Options | Terms | Ancillary Equipment | 1. Automatic Transfer Switch |
1. Emcp 4.2B | 1. 2 Year (Prime) | 2. Uninterruptible Power Supply | |||
2. Emcp 4.3 | 2. 3 Year | 3. Paralleling Switchgear | |||
3. Emcp 4.4 | 3. 5 Year | 4. Paralleling Controls | |||
Attachments | 4. 10 Year | Connectivity | |||
1. Local Annunciator Module | Coverage | 1. Ethernet | |||
2. Remote Annunciator Module | 1. Silver | 2. Cellular | |||
3. Expansion I/O Module | 2. Gold | 3. Satellite | |||
4. Remote Monitoring Software | 3. Platinum | 4. N/A | |||
5. N/A | 4. Platinum Plus | 5. N/A | |||
Fuel Tank | 1. 317 Gal (1200 L) | Charging | 1. Battery Charger – 5A | Certifications | 1. Eurasian Conformity (EAC) |
——END—— |
Standard Features of CAT 3516E-3250 Diesel Generator Set | |||
Generator Set Package | 1. Designed And Optimized For Low Fuel Consumption | Alternators | 1. Superior Motor Starting Capability Minimizes Need For Oversizing Generator |
2. Reliable Performance Proven In Thousands Of Applications Worldwide | 2. Designed To Match Performance And Output Characteristics Of Cat Diesel Engines | ||
Generator Set Package | 1. Accepts 100% Block Load In One Step And Meets Nfpa 110 Loading Requirements | EMCP 4 Control Panels | 1. User-Friendly Interface And Navigation |
2. Conforms To Iso 8528-5 G3 Load Acceptance Requirements | 2. Scalable System To Meet A Wide Range Of Installation Requirements | ||
3. Reliability Verified Through Torsional Vibration, Fuel Consumption, Oil Consumption, Transient,Performance, And Endurance Testing | 3. Expansion Modules And Site Specific Programming For Specific Customer Requirements | ||
Cooling System | 1. Cooling Systems Available To Operate In Ambient Temperatures Up To 50°C (122°F) | Worldwide Product Support | 1. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries |
2. Tested To Ensure Proper Generator Set Cooling | 2. Your Local Cat Dealer Provides Extensivepost-Sale Support, Including Maintenance And Repair Agreements | ||
Warranty | 1. 24 Months/1000-Hour Warranty For Standby And Mission Critical Ratings | Financing | 1. Caterpillar Offers An Array Of Financial Products To Help You Succeed Through Financial Service excel8lence |
2. 12 Months/Unlimited Hour Warranty For Prime And Continuous Ratings | 2. Options Include Loans, Finance Lease,Operating Lease, Working Capital, And Revolving Line Of Credit | ||
3. Extended Service Protection Is Available To Provide Extended Coverage Options | 3. Contact Your Local Cat Dealer For Availability In Your Region | ||
——END—— |
Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.
What's the Standard Scopes of Supply?
Cat Diesel Generator customize developing configurations for big vehicle OEMs in China, based on each of requirement, Cat producing dozens of different configuration Generator with same Generator model number, which only SO-Shop Order will be different with each other, the SO number is the identify number of the Generator configuration of each model.
Even with same Generator model, different SO number Generator can have very different configuration with each other, with different prices. Some of SO-Shop Order is not available for commercial market, such as restricted models (Usually for military specifications).
EMAC offering most common, cost effective models which also able to process the production in Cat, which usually have following accessories as standard configuration.
Cat Diesel Generator customize developing configurations for big vehicle OEMs in China, based on each of requirement, Cat producing dozens of different configuration Generator with same Generator model number, which only SO-Shop Order will be different with each other, the SO number is the identify number of the Generator configuration of each model.
Even with same Generator model, different SO number Generator can have very different configuration with each other, with different prices. Some of SO-Shop Order is not available for commercial market, such as restricted models (Usually for military specifications).
EMAC offering most common, cost effective models which also able to process the production in Cat, which usually have following accessories as standard configuration.
Scopes of Supply of CAT Diesel Generator | ||||
Air Intake System | 1. Air Intake Manifold | Exhuast System | 1. Exhuast Manifold | |
2. Water-Air Intercooler | 2. Turbocharger | |||
3. N/A | 3. Exhuast Elbow | |||
Fuel System | 1. Fuel Transfer Pump | Starting System | 1. Starter Motor | |
2. High-Pressure Fuel Pump | 2. Starter Rely | |||
3. Fuel Filter | 3. N/A | |||
Charging System | 1. Charging Alternator | Engine Shut-Down System | 1. Engine Puel Shut-Off Solenoid | |
Lubricating System | 1. Oil Pump | Cooling System | 1. Water Pump | |
2. Oil Filter | 2. Engine Fan | |||
3. N/A | 3. Standard Radiator | |||
Power Output System | 1. Flywheel | Engine Mounting System | 1. Engine Mouting Bracket | |
2. Standard Fflywheel Housing | 2. N/A | |||
Engine Auiliary Accessories | 1. Air Compressor | |||
2. Power Steering Pump | ||||
------END------ |
What's the Available Optional Items?
Cat only provides customize service for the large quantity orders or large OEMs, which means usually the order quantity are higher than 1000 units. For the small quantity Generator project, EMAC provides customize services with our own resource and Generator team.
EMAC have rich experience on the customize developing, which provides abundant optional items based on the requirement of each project. The typical optional items are special Prestolite charging alternator, prestolite starter motor, Knorr Air compressor. Valeo air conditioning compressor, ECU output socket set, Generator accelerate pedal etc.
Optional Accessories of CAT CAT Diesel Generator | ||||
Air Intake System | 1. Air Intake Pre-Heater | Exhuast System | 1. Muffler & Bellows | |
2. Air Intake Pre-Filter | 2. Flame Trap | |||
3. Air Filter Alarm System | 3. Spark Arrestor Type Muffler & Bellows | |||
4. N / A | 4. DPF System | |||
Fuel System | 1. Coarse Filter | Engine Auiliary Accessories | 1. Hydraulic Oil Pump | |
2. Fuel Pre-Heater | 2. Hydraulic Cluch | |||
Starting System | 1. Manual Magnetic DC Contactor | Cooling System | 1. Engine Monitor | |
2. Dual Ears Flywheel Housing | 2. Engine Protection System With Alarm System | |||
3. Spring Starter Motor | 3. Machanical Engine Control Lever Syste | |||
4. Air Starter Motor | 4. Electric Engine Control Lever System | |||
5. Hydraulic Starter Motor | 5. N / A | |||
6. Manual Magnetic DC Contactor | 6. N / A | |||
Power Output System | 1. Gear Reduction Gearbox | Cooling System | 1. Coolant Pre-Heater | |
2. Reverse Gear Box | 2. Jacket Water Heater | |||
Lubricating System | 1. Oil Pre-Heater | Engine Mounting System | 1. Shock Absorber Pad | |
------END------ |
Committed to providing reliable premium propulsion system and power system for all kinds of ships around the world, SeaMac is a sub-brand of EMAC group that focused on maritime application.
SeaMac's ranges of products mainly inclduing marine main Generator, marine gearbox, marine propellers, marine control lever system, marine auxiliary Generator, marine generator set and emergency generator set.
For more information of our marine proplusion and power system products, you are welcome to visit SeaMac homepage: www.seamac.com
What's the Modifiable Items and Scopes?
As explained in the standard scopes of supply, Cat not able to provide customize developing for small quantity projects or small OEMs, so EMAC helps SME OEMs to provide customize services, not only providing additional optional items, but also provides customize modification services to meet their requirements based on the exisiting Generator SO number.
As flexible service ability is our core advantages, EMAC is very experienced and good at providing customize services, the common customize services are as below:
1: AIr Intake System: Change the air intake direction.
2: Air Exhuast System: We are able to change the turbocharger direction as the interaction on installation could be occured, also change change the air exhuast direction.
3: Lubricating System: Modify lubricating system is one of the most common requirement from customer, we can provide flat-type Generator oil pan, to lower down total Generator height, which usually required for special vehicles. For the standard Generator oil pan, we also can change the direction of the Generator oil pan.
4: Cooling System: There are lots of options for the Generator cooling system, for the Generator fan, we can provide customize for the material of Generator fan (plastic fan or steel fan), wind direction of the Generator fan (blower fan or suction fan ) and types of Generator fan (mechanical fan or electric control fan).
5: Power Output System: Most of electronic controlled Cat marine Generator are comes with SAE#1 flywheel housing now, while lots of customers need SAE#2 flywheel because of the housing of transmissio is SAE#2, so we have to provide customzie services for those customer, which need to modify flywheel housing, flywheel and starter motor, we also have PTO integrated type flywheel housing available, which can output the whole power of the Generator from the PTO on the flywheel housing, we can also provide modification of the mounting side of the starter motor.
6: Electric System: All of Cat Generator are comes with standard 24V electric system, while some customer need to modify the electric system into 12V, we can also modify the starter motor and alternator into appointed brand or appointed specifications.
EMAC is your reliable professional power system partner, feel free to contact our services team to get detailed information about our standard scopes of supply, optional items and modifiable parts for our Cat marine Generator, we are ready to explore the journey of our cooperation.
Modifiable components of DCEC 6BT5.9-M120 Marine Main Engine | ||||
Air Intake System | 1. Installation Position of Air Filter | Starting System | 1. 12V Starter Motor for 12V Electric System | |
2. Upgrade to Heavy-Duty Type Air Fitler | 2. Upgrading to Specified Brand and Speicifications of Starter Motor | |||
Exhuast System | 1. Can Modify Installation Position and Direction of Turbocharger | Charging System | 1. 12V Charging Alternator for 12V Electric System | |
2. Water-Cooled Exhuast Manifold | 2. Explosion-Proof Charging Alternator | |||
3. Water-Cooled Turbocharger | 3. Upgrading to Specified Brand and Speicifications of Charging Alternator | |||
Fuel System | 1. Upgrade to Fuel Fitler That Integrated with Fuel Transfer Pump and Fuel Pre-Hearter | Engine Auiliary Accessories | 1. Additional Auxiliary Systems Can Be Added for Special Applications | |
Engine Shut-Down System | 1. 12V Solenoid for 12V Electric System | Cooling System | 1. Can Modify Engine Into Keel Cooling System | |
2. Explosion-Proof Solenoid | 2. N / A | |||
Lubricating System | 1. Oil Pan Position | Power Output System | 1. Can Modify Size of Flywheel Housing and Flywheel | |
2. Number of Dipstick | 2. Dual-Ear Flywheel Housing (For Twin-Starter System) | |||
3. Position of Dipstick Can Choose from 6 Positions | 3. Some of Models Can Modify Flywheel Housing Into PTO Integrated Type | |||
4. Can Modify Oil Filter to Be Remote Installation | 4. Engine Have Connecting Port of PTOs, That Able to Provide Power Output | |||
Engine Mounting System | 1. Can Modify Engine Mouting Bracket | |||
------END------ |
How to Order Generator to Replace Your Old Generator?
Type A: Generator Replacement Requirement (Original Generator is Cat Generator).
This is most simple demand case, you just need to provide us the original Generator name plate, and then we can easily check and confirm what exactly you need, and we also ensuring that the Generator from us will be 100% same with your original Generator. (In some case that the vehicle manufacturing modify the Generator on their own, we are not able to supply the parts or the condition that modified by the vehicle manufacturer)
Type B: Generator Replacement Requirement (Original Generator is Cat Generator but produced in UK, USA or other Cat Generator plant).
EMAC have rich experiences in replace the UK, USA or other Generator plant produced Generator, with Cat produced Cat Generator, we required the original Generator name plate photo to obtain the related information (at least we will need Generator serial number, with Generator model name only is useless for us, we are not able to provide quotation with Generator model name only for the replacement project), and then we can check out the BOM list and all accessories of your original Generator serial number, and then we can check and compare with the BOM list of our Cat produced Generator, choose the most closest SO number Generator, and modify the parts that not same with your original Generator, we have delivered hundreds of cases of replace the customer's original Generator that produced in Cat UK, USA or other Generator plants with Cat produced Generator, you can refer to our video introduction on Youtube: https://youtu.be/dYVgRM5NsUo
We can NOT guarantee the Generator produced by Cat is exactly same with your original Generator, but we can guarantee that all of Generator from EMAC will have no problem with installtion and performance, which all of Generator can works very well after replacement.
Type C: Generator Replacement Requirement (Original Generator is other brnad Generator even gasoline Generator).
EMAC also have rich experiences in replace the Generator that not Cat installed, these Generator can be other brands such as Deutz, Caterpillar, Perkins, Komatsu or others, we even had experiences of replace gasoline Generator with Cat produced diesel Generator.
This kind of appliaction is more complex and quite risky, EMAC can't do much thing due to lacking of information, the only thing we can guarantee is the performance after replacement, we check and compare the Generator performance curve of original Generator and our Cat Generator, and then we select the most suitable model for replacement. Due to we are lacking of the installation spaces and related accessories, we will send the both CAD and 3D drawing for our recommend Generator model, and then customer have to evaluate the risky of replace the original Generator with our Generator, especially the risky of space, the possibile interactive when installation, and the risky of modify related coolant pipe, air pipes and wiring harness. Normally this kind of request consuming lots of energy and resource for us to carry on, also quite risky for us, so we will not work on the replacement quantity that below 50 units.
When your requirement is replacement, please tell our customer service team of what type of replacement you need, and provide us original Generator name plate, the Generator name plate is the necessary material before we start our business negotiations, we will NOT reply to all inquiry that even can't provide Generator name plate.
How to Choose the Right CAT 50Hz Diesel Generator for You?
To choose a suitable Generator for truck, bus or special vehicle manufacturer is quite simple, because the buyer is the manufacturer, so usually they are quite flexible with space, pipes and wiring connections.
The following process are the standard process for us to select a suitable Generator model for truck, bus or special vehicle manufacturer demand.
Step 1: We need basic information of the required Generator, including rated power, rated speed and emission standard of the required Generator.
Step 2: EMAC will evaluate the requirement and select the suitable Generator model for customer, with Generator data sheet, Generator performance curve, CAD darwing, 3D model and budgetary quotation provided back to customer.
Step 3: Customer should check and compare the Generator data sheet, performance curve and related drawing and confirm all details one by one. Most important thing is confirm the performance curve suitable for the requirement.
Step 4: After Generator confirmed, we have to check and confirm the specifications of accessories one by one carefully, like the electric system specifications (12V or 24V), the detailed specifications of starter motor, charging alternator, air compressor, power steering pump, A/C compressor etc.
Step 5: Confirming the accessories positions and connections, customer need to check and confirm all positions are suitable for the project, such as Generator fan, turbocharger, oil pan position, and connections of air pipe, coolant pipe, wiring harness etc.
Step 6: After confirming the Generator performance, position, connection and specifications of all accessories, we will be able to provide accurate quotation for prototype and batch order. Prototype is strongly recommend to start the cooperation, to avoid the possible problem, risky on the Generator with batch order.
Notes:
1: Technical support including technical training, onsite installation and commissioning services are avaiable with additional chargers.
2: We are able to supply complete powertrain system, including Generator , transmission, transfer, axle, suspension etc, Generator with transmission is highly recommended, because if we supply both Generator and transmission, we can run simulations for the vehicle, which we usually will provide customer a simulation report, with the simulated result of Balanced Maximum Vehilce Speed and Maximum Grade Ability at different speed.
3: EMAC able supply complete chassis that integrate all powertrain system together, which can greatly reduce the manufacturer's design works and reduce the system mismatching risky.
Tips of CAT 50Hz Diesel Generator!
Cat is one of 50:50 joint venture of Cat in China, its official Cat factory that following high Cat USA production and quality control standard, the Cat factory swap every 5 years between appointed employee from Cat Motor and Cat. For more details, you can refer to the company introduction of Cat Generator Company.
Started the production of Cat Generator in China in 1980s, Cat products has been in China for over 40 years, thousands of people have worked for Cat China and some of them are very skilled experienced Generator, some of them resigned from Cat to set up their own small workshops or assembly factories that focusing on producing copy Cat Generator.
Price is always not the problem for Chinese suppliers, there are many tickies to lower down the Generator prices, such as supply self-rebuild Generator as new Generator, supply official RECON Generator from Cat as brand new Generator, assembly the fake Generator with after-market parts, supply lower power model Generator and change the name plate etc. You can find plenty of suppliers on alibaxx.com with various prices, the classic Chinese business style is tell you that he give you very low price and not make profit, how can you believe a businessman will make business that have no profit? They gave you low price not becuase they share their profit to you?
As a matter of fact, Chinese supplier often make their profit much more higher by selling the low quality copy products as genuine brand new products! Always remember YOU GET WHAT YOU PAID!
The key point of dealing with Chinese supplier, is to find and choose reliable business partner that will not cheat you for short-term business, but with vision of build long-term career and life-time partnership, EMAC is one of the reliable partner that not chasing for short-term high profit, but we cares our decades of good reputation and we working with all business partners not as supplier and customers, but as close friend and brothers.
FAQ of CAT 50Hz Diesel Generator?
CAT is the short name of Cat Generator Company, take the first letter of each word, it comes with CAT as short name, for more details about CAT , you can refer to the company introduction of CAT Generator Company.
2: Does your Generator copy products?
This question is quite often from customer that not familiar with CAT, CAT have over 20 joint ventures in China now, and 6 of them are Generator joint venture, which CAT owns 50% share of all of those 6 Generator plants, so all of the CAT factories in China are genuine CAT factory, that following high CAT USA production and quality control standard. EMAC is the business partner of CAT, and we are supplying powertrain and Generator power pack based on genuine brand new Generator from CAT for all different applications, EMAC is a reliable and professional power system solution provider that offering abundant various options.
3: Why there are so many companies selling CAT Generator?
There are plenty of companies selling CAT Generator in China, especially on the B2B platform, such as alibaxx.com, you can find plenty suppliers there with attractive prices, CAT products has been in China for over 40 years, thousands of people have worked for CAT China and some of them are very skilled experienced Generator, some of them resigned from CAT to set up their own small workshops or assembly factories that focusing on producing copy CAT Generator. You should be careful of being cheated by the attractive prices with copy or rebuild products.
4: How can I identify if the Generator genuine or not?
CAT keep working on the updating its identification system, technically, there are serial number on all key components of CAT Generator, including cylinder block, cylinder head, turbochager, fuel pump, starter motor, alternator, you can collecting the serial number (NOT part number), and then call CAT call service center to identify if all the numbers are matching to the original number or not. EMAC continuously updating the latest CAT identification system, you are welcome to following our website or keep in touch with our customer services team to get latest information from CAT.
5: What's the warranty policy for the Generator supplied by EMAC?
EMAC following standard CAT warranty policy, which will update sometimes, you can following us to get the latest warranty policy from CAT. Generally EMAC only afford the defective parts cots and shipping costs for the warranty claims, labor costs and transportation costs are not covered in the warranty.
However, EMAC is building our own independant after-sales service system now, which aims to build a global service network, with resouces of global repair and Generator network, which we believe can bring all business partner benifit in future, helping all of OEM manufacturers expanding their market into global market without worries of lacking after-sales service network. For more details about our Global Service, you can visiting www.global-service.com.
6: How about the future parts supply for the Generator? Are you able to supply parts?
As the support team of EMAC's business scope, PartMac is our own brand that focusing on genuine parts directly from all brand factories.
All of EMAC’s partners are facing big challenges with sourcing original spare parts in China. Committed to providing truthworthy and professional after-sales support and parts supply, PartMac is a sub-brand of EMAC group that focusing on parts business. Stick to original parts only, PartMac can’t give any solution on CHEAP PARTS, but you don’t need to worry about any quality issues with every single parts from PartMac.