Caterpillar DE33E0 Diesel Generator Set
CAT DE33E0 Diesel Generator Sets is a V-3-Cylinders 3.31 Liter (201.4 cu. in) Displacement Engine with 127.0 mm (5.0 in.) Bore and 127.0 mm (5.0 in.) Stroke.
Equipped with Dual Caterpillar® A3 Electronic Control Unit (ECU) LH with Electronic Unit Injector Fuel System Rigid Wiring Harness and ADEM™ A5 Governor.The Prime Power for 50 Hz Generator Set (1500 RPM) of CAT DE33E0 Diesel Generator Sets is 30.0 kVA (24.0 kW) and a Standby Power of 33.0 kVA (26.4 kW).
CAT DE33E0 Diesel Genset Powered by CAT Diesel Engine with EMCP 4 Control Panel, Diesel Genset with Turbocharged & Water-Air Intercooler.
CAT Diesel Generator Sets Meet Tier III/Tier IV Emission Standards. As Part of EMAC, CAT Diesel Generator Sets Also Provide 50 Hz and 60 Hz Diesel Generator Sets. Engine Brands Include Cummins, Deutz, Perkins, MTU, WeiChai and CAT.
Our Diesel Generator Set Series Includes High Power Medium and High Voltage Generator Sets and High Power Low Voltage Generator Sets. The Engine Provides Electronically Controlled and Mechanical Fuel Injection Systems for Customers to Choose. In Addition to Generating Diesel Generator Sets, We Can Also Supply Marine Diesel, Oil, Gas, Marine Generator Sets.
We Provide Full Life Cycle Services for All Customers, From Design to Power System Supply, From Installation to Commissioning, From After-Sales Service Training to Spare Parts Supply, From Troubleshooting to Overhaul Technical Support.
Advantages of Caterpillar DE33E0 Diesel GenSet
-
High power generation efficiency: The power generation efficiency of CAT Caterpillar gas-fired internal combustion generator sets is about 33-41%, and the efficiency of combined heat, power and cooling can reach more than 80%.
-
Low requirements for gas source: The gas internal combustion generator set has low requirements on the intake pressure (medium and low pressure) and intake temperature of the gas source, and has a wide range of calorific value.
-
Wide range of power used: Caterpillar gas internal combustion generator sets have a power range of 80 to 3480KW, which can operate as a single unit or in parallel with multiple units, grid-connected operation, and flexible station construction.
-
Wide range of adaptation to ambient temperature and altitude. At an ambient temperature of 40 degrees Celsius and an altitude of 500 meters, the rated power of the Caterpillar gas-fired internal combustion generator set is not compromised, and it can output 100%.
Technical Specifications
Basic Introduction of Cat DE33E0 Diesel Generator Sets
Genset Model: | DE33E0 |
Prime Power: | 30.0 kVA |
Genset Frequency: | 50 Hz |
Engine Model: | C3.3 |
Rated Power: | 30.0 kVA / 24.0 kW |
Alternator Brand: | N/A |
Alternator Model: | N/A |
Genset Dimension: | N/A |
Wet Weight: | 851 Kg |
Lead Time: | 15-30 Working Days |
Payment Terms: | T/T ,L/C |
Generrator Model |
Engine Model |
Standby |
Prime |
Generator Dimension |
DE33E0 | CAT C3.3 | 33.0 kVA / 26.4 kW | 30.0 kVA / 24.0 kW | 1540 kg / 60.6 in * 970 kg / 38.2 in * 1361 kg / 53.6 in |
——END—— |
Performance Data of CAT DE33E0 Diesel Generator Sets |
|||
Engine Model | DE33E0 | Generator Set Model – 3 Phase | 400/230 V, 50 Hz |
Prime | 30.0 kVA / 24.0 kW | Standby | 33.0 kVA / 26.4 kW |
Length | 1540 kg / 60.6 in | Net Weight (+ Lube Oil) | 838 kg / 1847 Ib |
Width | 970 kg / 38.2 in | Wet Weight (+ Lube Oil & Coolant) | 851 kg / 1876 Ib |
Height | 1361 kg / 53.6 in | Fuel, Lube Oil & Coolant | 987 kg / 2177 Ib |
Technical Data of CAT DE33E0 Diesel Generator Sets |
|||
Control Panel | EMCP 4.1 | Frequency | 50 Hz |
Base Frame Type | Heavy Duty Fabricated Steel | Engine Speed | 1500 rpm |
Circuit Breaker Type | 3 Pole MCB / 3 Pole MCCB | Fuel Tank Capacity | 161 Iitres / 42.5 gal |
Fuel Consumption – Standby | 7.7 I/hr / 2.0 gal/hr | Fuel Consumption – Prime | 6.9 I/hr / 1.8 gal/hr |
Generator Model | R1555L4 | ||
Physical Data of CAT DE33E0 Diesel Generator Sets |
|||
Manufacturer | Caterpillar | Engine Model | C3.3 |
No. of Cylinders/Alignment | 3 / In Line | Cycle | 4 Stroke |
Induction | Naturally Aspirated | Cooling Method | Water |
Governing Type | Mechanical | Governing Class | ISO 8528 G2 |
Compression Ratio | 19.25:1 | Displacement | 3.3 l / 201.4 cu.in |
Bore | 105.0 mm / 4.1 in | Stroke | 127.0 mm / 5.0 in |
Moment of Inertia | 1.14 kg.m² / 3896 lb.in² | No. of Bearings | 1 |
Dry Weight | 341 kg / 752 lb | Wet Weight | 348 kg / 767 lb |
Engine Electrical System-Voltage/Ground | 12 / Negative | Engine Electrical System-Battery Charger Amps: | 65 |
No. of Bearings | 1 | Insulation Class | H |
Winding Pitch – Code | 2/3 – MO | Excitation System | SHUNT |
Wires | 12 | AVR Model | Mark V |
Ingress Protection Rating | IP23 | ||
Operating Data of CAT DE33E0 Diesel Generator Sets |
|||
Overspeed | 2250 rpm | Total Harmonic Content LL/LN | 2.0% |
Voltage Regulation: (steady state) | +/- 0.5% | Wave Form IEC = THF | 2.0% |
Wave Form NEMA = TIF | 50 | Radiant Heat | 3.8 kW / 216 Btu/min |
Radio Interference | Suppression is in Line with European Standard EN61000-6 | ||
——END—— |
System Data of CAT DE33E0 Diesel Generator Set |
||||
Air System | Air Filter Type | Replaceable Element | Max. Combustion Air Intake Restriction | 6.5 kPa / 26.1 in H2O |
Combustion Air Flow – Standby | 2.2 m³/min / 76 cfm | RadiaTOr Cooling Air Flow | 62.6 m³/min / 2211 cfm | |
Combustion Air Flow – Prime | 2.2 m³/min / 76 cfm | External Restriction To Cooling Air Flow | 125 Pa / 0.5 in H2O | |
Cooling System | Cooling System Capacity | 10.2 l / 2.7 gal | Heat Rejected To Water & Lube Oil – Standby | 18.0 kW / 1024 Btu/min |
Water Pump Type | Centrifugal | Heat Rejected To Water & Lube Oil – Prime | 16.0 kW / 910 Btu/min | |
Heat Radiation To Room-Standby | 9.8 kW / 557 Btu/min | RadiaTOr Fan Load | 0.3 kW / 0.4 hp | |
Heat Radiation To Room-Prime | 8.1 kW / 461 Btu/min | |||
Lubrication System | Oil Filter Type | Spin-On, Full Flow | Oil Type | API CG4 / CH4 15W-40 |
Total Oil Capacity | 8.3 l / 2.2 gal | Cooling Method | Water | |
Oil Pan | 7.8 l / 2.1 gal | |||
Fuel System | Fuel Filter Type | Replaceable Element | Recommended Fuel | Class A2 Diesel Or BSEN590 |
Fuel Consumption Prime – 110% Load | 7.7 l/hr / 2.0 gal/hr | Fuel Consumption Standby – 110% Load | N/A | |
Fuel Consumption Prime – 100% Load | 6.9 l/hr / 1.8 gal/hr | Fuel Consumption Standby – 100% Load | 7.7 l/hr / 2.0 gal/hr | |
Fuel Consumption Prime – 75% Load | 5.2 l/hr / 1.4 gal/hr | Fuel Consumption Standby – 75% Load | 5.7 l/hr / 1.5 gal/hr | |
Fuel Consumption Prime – 0% Load | 3.8 l/hr / 1.0 gal/hr | Fuel Consumption Standby – 50% Load | 4.1 l/hr / 1.1 gal/hr | |
Exhaust System | Silencer Type | Industrial | Max. Allowable Back Pressure | 8.0 kPa / 2.4 in.Hg |
Silencer Model & Quantity | EXSY1 (1) | Exhaust Gas Flow – Prime | 5.7 m³/min / 201 cfm | |
Silencer NoIse Reduction Level | 20 dB | Exhaust Gas Temperature – Standby | 520 °C / 968 °F | |
Exhaust Gas Temperature – Prime | 500 °C / 932 °F | Pressure Drop Across Silencer System | 1.8 kPa / 0.532 in.Hg | |
Exhaust Gas Flow – Standby | 5.8 m³/min / 205 cfm | |||
PerfOrmance | Engine Speed | 1500 RPM | Regenerative Power | 7 |
Gross Engine Power – Standby | 31.0 KW / 42.0 hp | BMEP – Standby | 752.0 KW / 109.0 hp | |
Gross Engine Power – Prime | 28.2 KW / 38.0 hp | BMEP – Prime | 684.0 KW / 99.2 hp | |
Voltage | 415 / 240 V – Standby | 33.0 kVA / 36.4 kW | 415 / 240 V – Prime | 30.0 kVA / 24.0 kW |
400 / 230 V – Standby | 33.0 kVA / 36.4 kW | 400 / 230 V – Prime | 30.0 kVA / 24.0 kW | |
380 / 220 V – Standby | 33.0 kVA / 36.4 kW | 380 / 220 V – Prime | 30.0 kVA / 24.0 kW | |
230 / 115 V – Standby | 33.0 kVA / 36.4 kW | 230 / 115 V – Prime | 30.0 kVA / 24.0 kW | |
220 / 127 V – Standby | 33.0 kVA / 36.4 kW | 220 / 127 V – Prime | 30.0 kVA / 24.0 kW | |
220 / 110 V – Standby | 33.0 kVA / 36.4 kW | 220 / 110 V – Prime | 30.0 kVA / 24.0 kW | |
200 / 115 V – Standby | 33.0 kVA / 36.4 kW | 200 / 115 V – Prime | 30.0 kVA / 24.0 kW | |
——END—— |
Capacities of CAT DE33E0 Diesel Generator Set |
||||
Voltage | 415 / 240 V | 400 / 230V,230 / 115V,200 / 115 V | 380 / 220 V,220 / 110 V | 220 / 127 V |
MoTOr Starting Capability – kVA | 45 | 45 | 38 | 58 |
ShOrt Circuit Capacity – % | 300 | 300 | 300 | 300 |
Reactances Per Unit – Xd | 2.39 | 2.57 | 2.84 | 2.12 |
Reactances Per Unit- X’d | 0.22 | 0.23 | 0.26 | 0.19 |
Reactances Per Unit- X”d | 0.093 | 0.1 | 0.111 | 0.083 |
——END—— |
Ratings Definitions of CAT DE33E0 Diesel Generator Set |
|||
Standby | 1. Output Available With Varying Load For The Duration Of The Interruption Of The Normal Source Power. Average Power Outputis 70% Of The Standby Power Rating Typical Operation Is 200 Hours Per Year, With Maximum Expected Usage Of 500 Hours Per Year | Prime | 1. Output Available With Varying Load For An Unlimited Time. Average Power Output Is 70% Of The Prime Power Rating. Typical Peak Demand Is 100% Of Prime Rated Ekw With 10% Overload Capability For Emergency Use For A Maximum Of 1 Hour In 12. Overload Operation Cannot Exceed 25 Hours Per Year |
Fuel Rates | 1. Fuel Rates Are Based On Fuel Oil Of 35º Api [16°C (60ºf)] Gravity Having An Lhv Of 42,780 Kj/Kg (18,390 Btu/Lb) When Used At 29ºc (85ºf) And Weighing 838.9 G/Liter (7.001 Lbs/U.S. Gal.) | Applicable Codes and Standards | 1. As 1359, Csa C22.2 No. 100-04, Ul 142, Ul 489,Ul 869, Ul 2200, Nfpa 37, Nfpa 70, Nfpa 99, Nfpa 110, Ibc, Iec 60034-1, Iso 3046, Iso 8528, Nema Mg1-22, Nema Mg1-33, 2014/35/Eu, 2006/42/Ec, 2014/30/Eu |
Data Center Applications | 1. Lso 8528-1 Data Center Power (Dcp) Compliant Per Dcp Application Of Cat Diesel Generator Set Prime Power Rating | ||
2. All Ratings Tier Iii/Tier Iv Compliant Per Uptime Institute Requirements | |||
3. All Ratings Ansi/Tia-942 Compliant For Rated-1 Through Rated-4 Data Centers | |||
——END—— |
Optional Equipment of CAT DE33E0 Diesel Generator Set |
|||||
Engine | Air Cleaner | Power Termination | Type | Alternator | Output Voltage |
1. Single Element | 1. Bus Bar | 1. 380 V | |||
2. Dual Element | 2. Circuit Breaker | 2. 400 V | |||
3. Heavy Duty | 3. 1250 A | 3. 415 V | |||
Muffler | 4. 1600 A | Temperature Rise(Over 40°C Ambient) | |||
1. Industrial Grade (10 Db) | 5. 2500 A | 1. 125 °C | |||
Starting | 6. 3-Pole | 2. 105 °C | |||
1. Standard Batteries | 7. Iec | 3. 3.08 °C | |||
2. Oversized Batteries | 8. Manually Operated | Winding Type | |||
3. Heavy Duty Electric Starter(S) | 9. Electrically Operated | 1. Random Wound | |||
4. Dual Electric Starter(S) | Trip Unit | Excitation | |||
5. Jacket Water Heater | 1. Lsi | 1. Self Excited | |||
6. N/A | 2. N/A | 2. Permanent Magnet (Pm) | |||
Control System | Controller | Extended Service Options | Terms | Ancillary Equipment | 1. Automatic Transfer Switch |
1. Emcp 4.2B | 1. 2 Year (Prime) | 2. Uninterruptible Power Supply | |||
2. Emcp 4.3 | 2. 3 Year | 3. Paralleling Switchgear | |||
3. Emcp 4.4 | 3. 5 Year | 4. Paralleling Controls | |||
Attachments | 4. 10 Year | Connectivity | |||
1. Local Annunciator Module | Coverage | 1. Ethernet | |||
2. Remote Annunciator Module | 1. Silver | 2. Cellular | |||
3. Expansion I/O Module | 2. Gold | 3. Satellite | |||
4. Remote Monitoring Software | 3. Platinum | 4. N/A | |||
5. N/A | 4. Platinum Plus | 5. N/A | |||
Fuel Tank | 1. 317 Gal (1200 L) | Charging | 1. Battery Charger – 5A | Certifications | 1. Eurasian Conformity (EAC) |
——END—— |
Standard Features of CAT DE33E0 Diesel Generator Set |
|||
Generator Set Package | 1. Designed And Optimized For Low Fuel Consumption | Alternators | 1. Superior Motor Starting Capability Minimizes Need For Oversizing Generator |
2. Reliable Performance Proven In Thousands Of Applications Worldwide | 2. Designed To Match Performance And Output Characteristics Of Cat Diesel Engines | ||
Generator Set Package | 1. Accepts 100% Block Load In One Step And Meets Nfpa 110 Loading Requirements | EMCP 4 Control Panels | 1. User-Friendly Interface And Navigation |
2. Conforms To Iso 8528-5 G3 Load Acceptance Requirements | 2. Scalable System To Meet A Wide Range Of Installation Requirements | ||
3. Reliability Verified Through Torsional Vibration, Fuel Consumption, Oil Consumption, Transient,Performance, And Endurance Testing | 3. Expansion Modules And Site Specific Programming For Specific Customer Requirements | ||
Cooling System | 1. Cooling Systems Available To Operate In Ambient Temperatures Up To 50°C (122°F) | Worldwide Product Support | 1. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries |
2. Tested To Ensure Proper Generator Set Cooling | 2. Your Local Cat Dealer Provides Extensivepost-Sale Support, Including Maintenance And Repair Agreements | ||
Warranty | 1. 24 Months/1000-Hour Warranty For Standby And Mission Critical Ratings | Financing | 1. Caterpillar Offers An Array Of Financial Products To Help You Succeed Through Financial Service excel7935731lence |
2. 12 Months/Unlimited Hour Warranty For Prime And Continuous Ratings | 2. Options Include Loans, Finance Lease,Operating Lease, Working Capital, And Revolving Line Of Credit | ||
3. Extended Service Protection Is Available To Provide Extended Coverage Options | 3. Contact Your Local Cat Dealer For Availability In Your Region | ||
——END—— |