Caterpillar DE200E0 Diesel Generator Set
CAT DE200E0 Diesel Generator Sets is a V-4-Cylinders 7 Liter (427.8 in³) Displacement Engine with 10.5 mm (4.1 in.) Bore and 135.0 mm (5.3 in.) Stroke.
Equipped with Dual Caterpillar® A3 Electronic Control Unit (ECU) LH with Electronic Unit Injector Fuel System Rigid Wiring Harness and ADEM™ A5 Governor.The Prime Power for 60 Hz Generator Set (1800 RPM) of CAT DE200E0 Diesel Generator Sets is 200 kVA (160 kW) and a Standby Power of 218.8 kVA (175.0 kW).
CAT DE200E0 Diesel Genset Powered by CAT Diesel Engine with EMCP 4 Control Panel, Diesel Genset with Turbocharged & Water-Air Intercooler.
CAT Diesel Generator Sets Meet Tier III/Tier IV Emission Standards. As Part of EMAC, CAT Diesel Generator Sets Also Provide 50 Hz and 60 Hz Diesel Generator Sets. Engine Brands Include Cummins, Deutz, Perkins, MTU, WeiChai and CAT.
Our Diesel Generator Set Series Includes High Power Medium and High Voltage Generator Sets and High Power Low Voltage Generator Sets. The Engine Provides Electronically Controlled and Mechanical Fuel Injection Systems for Customers to Choose. In Addition to Generating Diesel Generator Sets, We Can Also Supply Marine Diesel, Oil, Gas, Marine Generator Sets.
We Provide Full Life Cycle Services for All Customers, From Design to Power System Supply, From Installation to Commissioning, From After-Sales Service Training to Spare Parts Supply, From Troubleshooting to Overhaul Technical Support.
Advantages of Caterpillar DE200E0 Diesel GenSet
-
It is synchronized with Cummins’ advanced design and sophisticated manufacturing, adapts to harsh working conditions, and has high-intensity and heavy-duty work capabilities.
-
The Holset wastegate valve makes the low speed performance more perfect and the power performance better.
-
The cylinder block and cylinder head adopt integrated design to prevent the occurrence of engine water and oil leakage. The parts are 40% less than other similar engines, and the failure rate is greatly reduced.
-
Using forged steel camshaft and crankshaft, high-strength cylinder design, many parts are cast on the cylinder, with high rigidity, high pressure resistance, good reliability and longer service life.
-
The cylinder liner adopts a platform mesh honing design, which effectively prevents oil leakage with a perfect geometric structure, and adopts advanced technology such as new piston ring components and gasket crimping molding to reduce oil loss.
-
Holset supercharger with integrated wastegate valve, low speed response and strong power.
Technical Specifications
Basic Introduction of CAT DE200E0 Diesel Generator Set
Genset Model: | DE200E0 |
Prime Power: | 200 kVA |
Genset Frequency: | 60 Hz |
Engine Model: | C7.1 In-line 6, 4-cycle diesel |
Rated Power: | 1800 r/min @ 180.5 kW |
Alternator Brand: | Leroy N/A |
Alternator Model: | N/A |
Genset Dimension: | 2500 mm * 1320 mm * 1626 mm |
Wet Weight: | 1723 Kg |
Lead Time: | 15-30 Working Days |
Payment Terms: | T/T ,L/C |
General Information of CAT DE200E0 Diesel Generator Set |
|||
Engine Model | CAT C7.1 In-line 6, 4-Cycle Diesel | Displacement | 7.0 L / 427.8 in³ |
Bore | 105 mm / 4.1 in | Stroke | 135 mm / 5.3 in |
Compress Ratio | 16.0:1 | Voltage / Frequency | 480 / 277 V, 60 Hz |
Aspiration | Turbocharged Water Cooled | Governor Type | Mechanical |
Standby | 218.8 kVA / 175 ekW | Prime | 200 kVA / 160 ekW |
Length | 2500 mm / 98.4 in | Width | 1320 mm / 52.0 in |
Height | 1626 mm / 64.0 in | Net (+ Lube Oil) | 1696 kg / 3739 lb |
Wet (+ lube oil & coolant) | 1723 kg / 3799 lb | Fuel, lube Oil & Coolant | 2500 kg / 98.4 lb |
Emissions Performance | Non-Certified Emissions | ||
Physical Data of CAT DE200E0 Diesel Generator Set |
|||
Frame Model | R2455L4 | Winding Pitch-Code | 2/3 – M0 |
No. of Bearings | 1 | Excitation | SHUNT |
Wires | 0012 | AVR Model | Mark V |
IP Rating & Insulation Class | IP23 & H | ||
Operating Data of CAT DE200E0 Diesel Generator Set |
|||
Overspeed | 2250 RMP | Total Harmonic Content LL/LN | 2.0 % |
Voltage Regulation: (steady state) | +/- 0.5 % | Wave Form IEC = THF | 2.0 % |
Wave Form NEMA = TIF | 50 | Radiant Heat | 14.6 kW / 830 Btu/min |
Radio Interference | Suppression Is In line With European Standard EN61000-6 | ||
——END—— |
Package Performance of CAT DE200E0 Diesel Generator Set |
|||
Standby | Prime | ||
Technical Data | Engine Speed — RPM | 1800 | 1800 |
Gross Engine Power — kW (hp) | 199.7 / 268.0 | 180.5 / 242.0 | |
BMEP — kPa (psi) | 1898.0 / 275.3 | 1715.0 / 248.8 | |
Regenerative Power — kW | N/A | N/A | |
Fuel System | 100% Load — L/hr (gal/hr) | N/A | 50.6 / 13.4 |
75% Load — L/hr (gal/hr) | 50.6 / 13.4 | 46.5 / 12.3 | |
50% Load — L/hr (gal/hr) | 38.6 / 10.2 | 35.4 / 9.4 | |
25% Load — L/hr (gal/hr) | 26.0 / 6.9 | 23.6 / 6.2 | |
Fuel Filter Type | Replaceable Element | Replaceable Element | |
Recommended Fuel | Class A2 Diesel Or BSEN590 | Class A2 Diesel Or BSEN590 | |
Air System | Combustion Air Flow — m³/min (cfm) | 16.4 / 578 | 15.5 / 546 |
Max. Combustion Air intake restriction — kPa (in H2O) | 3.0 / 12.0 | 3.0 / 12.0 | |
Radiator Cooling Air flow — m³/min (cfm) | 307.2 / 10849 | 307.2 / 10849 | |
External Restriction to Cooling Air Flow — Pa (in H2O) | 125 / 0.5 | 125 / 0.5 | |
Air Filter Type | Paper Element | Paper Element | |
Cooling System2 | Heat Rejected To Water & Lube Oil — kW (Btu/min) | 88.3 / 5022 | 81.5 / 4635 |
Heat Radiated From Engine & Alternator — kW (Btu/min) | 34.1 / 1939 | 30.3 / 1723 | |
Cooling System Capacity — l (gal) | 27.0 / 7.1 | 27.0 / 7.1 | |
Radiator Fan Load — kW (hp) | 10.0 / 13.4 | 10.0 / 13.4 | |
Water Pump Type | Centrifugal | Centrifugal | |
Exhaust System | Exhaust Gas Flow — m³/min (cfm) | 38.4 / 1354 | 35.4 / 1251 |
Exhaust Gas Temperature — °C (°F) | 485 / 905 | 485 / 905 | |
Pressure Drop Across Silencer System — kPa (in.Hg) | N/A | N/A | |
Silencer Noise Reduction Level — dB | 10 | 10 | |
Max. Allowable Back Pressure — kPa (in. Hg) | 6.0 / 1.8 | 6.0 / 1.8 | |
Silencer Type | Industrial | Industrial | |
Silencer Model & Quantity | EXSY1 (1) | EXSY1 (1) | |
Voltage | |||
Capacities | 480/277V — kVA (kW) | 200 / 160 | 218.8 / 175 |
220/127V — kVA (kW) | 200 / 160 | 218.8 / 175 | |
380/220V — kVA (kW) | 195 / 156 | 215 / 172 | |
240/120V — kVA (kW) | 199.5 / 159.6 | 218.8 / 175 | |
220/110V — kVA (kW) | 195 / 156 | 215 / 172 | |
208/120V — kVA (kW) | 200 / 160 | 218.8 / 175 | |
240/139V — kVA (kW) | 199.5 / 159.6 | 218.8 / 175 | |
——END—— |
Voltage of CAT DE200E0 Diesel Generator Set |
||||
Voltage | 480 / 277 V,240 / 139 V | 380 / 220 V,220 / 110 V | 240 / 120V,208 / 120 V | 440 / 254 V,220 / 127 V |
Motor Starting Capability — kVA | 237 | 170 | 194 | 212 |
Short Circuit Capacity — % | 300 | 300 | 300 | 300 |
Reactances Per Unit – Xd | 3.02 | 4.716 | 4.034 | 3.617 |
Reactances Per Unit- X’d | 0.259 | 0.402 | 0.343 | 0.308 |
Reactances Per Unit- X”d | 0.104 | 0.161 | 0.138 | 0.123 |
——END—— |
Ratings Definitions of CAT DE200E0 Diesel Generator Set |
|||
Standby | 1. Output Available With Varying Load For The Duration Of The Interruption Of The Normal Source Power. Average Power Outputis 70% Of The Standby Power Rating Typical Operation Is 200 Hours Per Year, With Maximum Expected Usage Of 500 Hours Per Year | Prime | 1. Output Available With Varying Load For An Unlimited Time. Average Power Output Is 70% Of The Prime Power Rating. Typical Peak Demand Is 100% Of Prime Rated Ekw With 10% Overload Capability For Emergency Use For A Maximum Of 1 Hour In 12. Overload Operation Cannot Exceed 25 Hours Per Year |
Fuel Rates | 1. Fuel Rates Are Based On Fuel Oil Of 35º Api [16°C (60ºf)] Gravity Having An Lhv Of 42,780 Kj/Kg (18,390 Btu/Lb) When Used At 29ºc (85ºf) And Weighing 838.9 G/Liter (7.001 Lbs/U.S. Gal.) | Applicable Codes and Standards | 1. As 1359, Csa C22.2 No. 100-04, Ul 142, Ul 489,Ul 869, Ul 2200, Nfpa 37, Nfpa 70, Nfpa 99, Nfpa 110, Ibc, Iec 60034-1, Iso 3046, Iso 8528, Nema Mg1-22, Nema Mg1-33, 2014/35/Eu, 2006/42/Ec, 2014/30/Eu |
Data Center Applications | 1. Lso 8528-1 Data Center Power (Dcp) Compliant Per Dcp Application Of Cat Diesel Generator Set Prime Power Rating | ||
2. All Ratings Tier Iii/Tier Iv Compliant Per Uptime Institute Requirements | |||
3. All Ratings Ansi/Tia-942 Compliant For Rated-1 Through Rated-4 Data Centers | |||
——END—— |
Optional Equipment of CAT DE200E0 Diesel Generator Set | |||||
Engine | Air Cleaner | Power Termination | Type | Alternator | Output Voltage |
1. Single Element | 1. Bus Bar | 1. 380 V | |||
2. Dual Element | 2. Circuit Breaker | 2. 400 V | |||
3. Heavy Duty | 3. 1250 A | 3. 415 V | |||
Muffler | 4. 1600 A | Temperature Rise(Over 40°C Ambient) | |||
1. Industrial Grade (10 Db) | 5. 2500 A | 1. 125 °C | |||
Starting | 6. 3-Pole | 2. 105 °C | |||
1. Standard Batteries | 7. Iec | 3. 3.08 °C | |||
2. Oversized Batteries | 8. Manually Operated | Winding Type | |||
3. Heavy Duty Electric Starter(S) | 9. Electrically Operated | 1. Random Wound | |||
4. Dual Electric Starter(S) | Trip Unit | Excitation | |||
5. Jacket Water Heater | 1. Lsi | 1. Self Excited | |||
6. N/A | 2. N/A | 2. Permanent Magnet (Pm) | |||
Control System | Controller | Extended Service Options | Terms | Ancillary Equipment | 1. Automatic Transfer Switch |
1. Emcp 4.2B | 1. 2 Year (Prime) | 2. Uninterruptible Power Supply | |||
2. Emcp 4.3 | 2. 3 Year | 3. Paralleling Switchgear | |||
3. Emcp 4.4 | 3. 5 Year | 4. Paralleling Controls | |||
Attachments | 4. 10 Year | Connectivity | |||
1. Local Annunciator Module | Coverage | 1. Ethernet | |||
2. Remote Annunciator Module | 1. Silver | 2. Cellular | |||
3. Expansion I/O Module | 2. Gold | 3. Satellite | |||
4. Remote Monitoring Software | 3. Platinum | 4. N/A | |||
5. N/A | 4. Platinum Plus | 5. N/A | |||
Fuel Tank | 1. 317 Gal (1200 L) | Charging | 1. Battery Charger – 5A | Certifications | 1. Eurasian Conformity (EAC) |
——END—— |
Standard Features of CAT DE200E0 Diesel Generator Set |
|||
Generator Set Package | 1. Designed And Optimized For Low Fuel Consumption | Alternators | 1. Superior Motor Starting Capability Minimizes Need For Oversizing Generator |
2. Reliable Performance Proven In Thousands Of Applications Worldwide | 2. Designed To Match Performance And Output Characteristics Of Cat Diesel Engines | ||
Generator Set Package | 1. Accepts 100% Block Load In One Step And Meets Nfpa 110 Loading Requirements | EMCP 4 Control Panels | 1. User-Friendly Interface And Navigation |
2. Conforms To Iso 8528-5 G3 Load Acceptance Requirements | 2. Scalable System To Meet A Wide Range Of Installation Requirements | ||
3. Reliability Verified Through Torsional Vibration, Fuel Consumption, Oil Consumption, Transient,Performance, And Endurance Testing | 3. Expansion Modules And Site Specific Programming For Specific Customer Requirements | ||
Cooling System | 1. Cooling Systems Available To Operate In Ambient Temperatures Up To 50°C (122°F) | Worldwide Product Support | 1. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries |
2. Tested To Ensure Proper Generator Set Cooling | 2. Your Local Cat Dealer Provides Extensivepost-Sale Support, Including Maintenance And Repair Agreements | ||
Warranty | 1. 24 Months/1000-Hour Warranty For Standby And Mission Critical Ratings | Financing | 1. Caterpillar Offers An Array Of Financial Products To Help You Succeed Through Financial Service excel7935731lence |
2. 12 Months/Unlimited Hour Warranty For Prime And Continuous Ratings | 2. Options Include Loans, Finance Lease,Operating Lease, Working Capital, And Revolving Line Of Credit | ||
3. Extended Service Protection Is Available To Provide Extended Coverage Options | 3. Contact Your Local Cat Dealer For Availability In Your Region | ||
——END—— |