Caterpillar CG170-12 Gas Generator Set
CAT CG170-12 Gas Generator Set is a V-12-Cylinders 53 L iter Displacement Engine with 170.0 mm Bore and 195.0 mm Stroke.
Equipped with Dual Caterpillar® A3 Electronic Control Unit (ECU) LH with Electronic Unit Injector Fuel System Rigid Wiring Harness and ADEM™ A5 Governor.The Prime Power for 50 Hz Generator Set (1500 RPM) of CAT CG170-12 Diesel Generator Sets is 725 kVA (850 kW). and a Standby Power of 810 kVA (648 kW).
CAT CG170-12 Diesel Genset Powered by CAT Diesel Engine with EMCP 4 Control Panel, Diesel Genset with Turbocharged-Aftercooled.
CAT Diesel Generator Sets Meet Tier III/Tier IV Emission Standards. As Part of EMAC, CAT Diesel Generator Sets Also Provide 50 Hz and 60 Hz Diesel Generator Sets. Engine Brands Include Cummins, Deutz, Perkins, MTU, WeiChai and CAT.
Our Diesel Generator Set Series Includes High Power Medium and High Voltage Generator Sets and High Power Low Voltage Generator Sets. The Engine Provides Electronically Controlled and Mechanical Fuel Injection Systems for Customers to Choose. In Addition to Generating Diesel Generator Sets, We Can Also Supply Marine Diesel, Oil, Gas, Marine Generator Sets.
We Provide Full Life Cycle Services for All Customers, From Design to Power System Supply, From Installation to Commissioning, From After-Sales Service Training to Spare Parts Supply, From Troubleshooting to Overhaul Technical Support.
Advantages of Caterpillar CG170-12 Gas GenSet
-
Engine Design : Proven reliability and durability, Ability to burn a wide spectrum of gaseous fuels, Robust diesel strength design prolongs life and lowers owning and operating costs, Broad operating speed range.
-
Advanced Digital Engine Management : ADEM A3 control system providing integrated ignition, speed governing, protection, and controls, including detonation-sensitive variable ignition timing. ADEM A3 has improved: user interface, display system, shutdown controls, and system diagnostics.
-
Lean Burn Engine Technology : Lean-burn engines operate with large amounts of excess air. The excess air absorbs heat during combustion reducing the combustion temperature and pressure, greatly reducing levels of NOx. Lean-burn design also provides longer component life and excellent fuel consumption.
-
Ease of Operation : Side covers on block allow for inspection of internal components.
-
Full Range of Attachments : Large variety of factory-installed engine attachments reduces packaging time.
-
Testing : Every engine is full-load tested to ensure proper engine performance.
Technical Specifications
Basic Introduction of CAT CG170-12 Gas Generator Set
Engine Model: | CG170-12 |
Engine Type: | V-12 Cylinders |
Displacement: | 53 L |
Rated Speed: | 1500 RPM |
Aspiration Method: | Turbocharged-Aftercooled |
Emission Standard: | N/A |
Bore*Storke: | 170 mm * 195 mm |
Packing Size(L*W*H): | 5970 mm * 1778 mm * 2210 mm |
Wet Weight: | 10600 Kg |
Lead Time: | 15-30 Working Days |
Payment Terms: | T/T ,L/C |
Genset Information of CAT CG170-12 Gas Generator Set |
|||
Engine Model | CG170-12 | Speed | 1500 1/min |
Configuration / Number of Cylinders | V / 12 | Engine-Management-System | TEM EVO |
Bore / Stroke / Displacement | 170 mm / 195 mm / 53 dm3 | Generator | Marelli MJB 450 LB4 |
Compression Ratio | 13.5:0 | Voltage / Voltage Range / Cos Phi | 400 V / ±5 % / 1 |
Mean Piston Speed | 9.8 m/s | Frequency | 50 Hz |
Mean Lube Oil Consumption at Full Load | 0.2 g/kWh | Length / Width / Height | 5970 mm / 1778 mm / 2210 mm |
Comb. Air Temperature / Rel. Humidity | 25 °C / 60 % | Methane Number | 80 |
Altitude | 100 m | Lower Calorific Value | 10.19 kWh/Nm3 |
Exhaust Temp. After Heat Exchanger | 120 °C | Gas Density | 0.80 kg/Nm3 |
NOx Emission (Tolerance – 8%) | 500 mg/Nm³ @ 5%O2 | Standard Gas | Natural Gas, MN = 80 |
Aspiration | TA | ||
——END—— |
Energy Balance Information of CAT CG170-12 Gas Generator Set |
|||||||
Load (%) | 100 | 75 | 50 | Load (%) | 100 | 75 | 50 |
Electrical Power COP Acc. ISO 8528-1 (kW) | 1200 | 900 | 600 | Exhaust Mass Flow, Wet (kg/h) | 6476 | 4896 | 3373 |
Engine Jacket Water Heat (kW ±8%) | 608 | 468 | 335 | Combustion Mass Air Flow (kg/h) | 6262 | 4730 | 3257 |
Intercooler LT Heat (kW ±8%) | 106 | 71 | 41 | Radiation Heat Engine / Generator (kW ±8%) | 41 / 32 | 40 / 25 | 36 / 20 |
Lube Oil Heat (kW ±8%) | N/A | N/A | N/A | Fuel Consumption (kW+5%) | 2748 | 2119 | 1487 |
Exhaust Heat With Temp. After Heat Exchanger (kW ±8%) | 581 | 480 | 363 | Electrical / Thermal Efficiency (%) | 43.7 / 43.3 | 42.5 / 44.7 | 40.3 / 46.9 |
Exhaust Temperature (°C ±25°C) | 414 | 440 | 470 | Total Efficiency (%) | 87 | 87.2 | 87.3 |
——END—— |
System Parameters Information of CAT CG170-12 Gas Generator Set |
|||
Ventilation Air Flow (Comb. Air Incl.) With ΔT = 15K | 30000 kg/h | Pre-Pressure Gas Control Unit Selectable From / To | 0.5 bar / 10 bar |
Combustion Air Temperature Minimum / Design | 20 / 25 | Starter Battery 24V, Capacity Required | 430 Ah |
Exhaust Back Pressure From / To | 30 / 50 | Starter Motor | 15 kWel. / 24 VDC |
Maximum Pressure Loss in Front of Air Cleaner | 5 | Lube Oil Content Engine / Base Frame | 205 dm3 / N/A |
Zero-Pressure Gas Control Unit Selectable From / To | 20 / 200 | Dry Weight Engine / Genset | 5080 kg / 10600 kg |
Cooling system Information of CAT CG170-12 Gas Generator Set |
|||
Glycol Content Engine Jacket Water / Intercooler | 0 / 35 Vol. | Intercooler Coolant Temperature In / Out | 40 °C / 43 °C |
Water Volume Engine Jacket / Intercooler | 111 dm3 / 20 dm3 | Engine Jacket Water Flow Rate From / To | 36 m3/h / 56 m3/h |
KVS / Cv Value Engine Jacket Water / Intercooler | 42 m3/h / 30 m3/h | Water Flow Rate Engine Jacket Water / Intercooler | 41 m3/h / 35 m3/h |
Jacket Water Coolant Temperature In / Out | 80 °C / 93 °C | Water Pressure Loss Engine Jacket Water / Intercooler | 0.9 bar / 1.4 bar |
——END—— |
Frequency of CAT CG170-20 Gas Generator Set |
|||||||||
Octave Band Centre Frequency | |||||||||
Engine Noise Level | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Sum Level (Distance Meter) |
Exhaust Noise [dB(lin)] | 116 | 123 | 122 | 119 | 111 | 110 | 108 | 107 | 120 dB(A) (±2.5 dB(A)) |
Air-Borne Noise [dB(lin)] | 92 | 104 | 104 | 100 | 99 | 96 | 99 | 99 | 106 dB(A) (±1.0 dB(A)) |
——END—— |
Performance Overview of CAT CG170-12 Gas Generator Set |
|||
High Efficiency | 1. Products With Similar Output Grades Are Most Efficient | Lower installation,Construction | 1. Oil Consumption Is Less Than 0.1G/Kw |
2. Electrical Efficiency Increased By 42.5% | 2. Compared With Similar Models, Lubricant Consumption Is Reduced By 66% | ||
3. The Vibration And Stress Of The Components Are Reduced | 3. Longer Lubricant Change Cycle (Up To 4000h) And Oil Change Cycle | ||
Floor Space | 1. CG Takes Up Less Space | System Control | 1. Cat Total Electronic Management System |
2. Low Installation Cost | 2. Realize The Overall System Monitoring | ||
lubrication Oil Consumption | 1. Compact Design With Integrated Fuel Tank | Higher Availability | 1. Use of Pre-Ignition Spark Plug to Achieve Particle – Free Combustion |
2. Meet Daily Filling Requirements | 2. Extending The Maintenance Period | ||
3. Lower Installation Costs | 3. Improve Work Efficiency | ||
4. Long Maintenance Cycle (Up To 80,000 Hours) | 4. Extend The Annual Operating Time | ||
5. Optimized Oil Management | |||
6. Investment Costs Are Reduced Through Expanded Product Range And TPEM Digital Control Systems | |||
——END—— |
Standard of CAT CG170-12 Gas Generator Set |
|||
Inlet Air | 1. Single Filter Element Single Stage Air Cleaner With Housing And Maintenance Indicator | Start/Charge | 1. 24V Starter Motor |
2. Turbochargers, All Cylinders Are Equipped With Water-Cooled Bearing Boxes | 2. Battery Break Switch | ||
Exhaust | 1. Exhaust Gas Door Of CG170-12 | Fuel System | 1. Individually Controlled Cylinder Monitoring And Ignition System |
2. Enclosed Crankcase Ventilation System | 2. Electronic Fuel Metering Valve | ||
3. Pearl/ Low Resistance Exhaust System | 3. Precombustion Chamber Spark Plug | ||
Control Panel | 1. Tpem (Whole-Plant Energy Management System) | General | 1. Crankshaft Shock Absorber And Shield |
Generator | 1. Anti-Condensation Space Heater | Cooling | 1. Flange Joints For Jw Inlet And Outlet |
2. Reactive Pressure Drop | 2. Electric Water Jacket Water And Aftercooler Coolant Pump | ||
3. Generator Grid Criteria | 3. Water Jacket Water And Scac Thermostat | ||
4. Winding Temperature Detector | |||
5. Busbar Connection | |||
6. Three-Phase Induction And Kvar/Pf Control Unit | |||
7. The Directly Connected Generator Can Achieve No Torque Transmission To The Base Frame | |||
——END—— |