Select Page

Caterpillar 3512B-1625 Diesel Generator Set

CAT 3512B-1625 Diesel Generator Sets is a V-4-Cylinders 51.8 Liter (3161.03 in³) Displacement Engine with 190.0 mm (7.48 in.) Bore and 190.0 mm (7.48 in.) Stroke.

Equipped with Dual Caterpillar® A3 Electronic Control Unit (ECU) LH with Electronic Unit Injector Fuel System Rigid Wiring Harness and ADEM™ A5 Governor.The Prime Power for 50 Hz Generator Set (1500 RPM) of CAT 3512B-1625 Diesel Generator Sets is 1500.0 kVA (1200.0 kW) and a Standby Power of 1625.0 kVA (1300.0 kW).

CAT 3512B-1625 Diesel Genset Powered by CAT Diesel Engine with EMCP 4 Control Panel, Diesel Genset with Turbocharged & Water-Air Intercooler.

CAT Diesel Generator Sets Meet Tier III/Tier IV Emission Standards. As Part of EMAC, CAT Diesel Generator Sets Also Provide 50 Hz and 60 Hz Diesel Generator Sets. Engine Brands Include Cummins, Deutz, Perkins, MTU, WeiChai and CAT.

Our Diesel Generator Set Series Includes High Power Medium and High Voltage Generator Sets and High Power Low Voltage Generator Sets. The Engine Provides Electronically Controlled and Mechanical Fuel Injection Systems for Customers to Choose. In Addition to Generating Diesel Generator Sets, We Can Also Supply Marine Diesel, Oil, Gas, Marine Generator Sets.

We Provide Full Life Cycle Services for All Customers, From Design to Power System Supply, From Installation to Commissioning, From After-Sales Service Training to Spare Parts Supply, From Troubleshooting to Overhaul Technical Support.

Advantages of Caterpillar 3512B-1625 Diesel GenSet

  • High power generation efficiency: The power generation efficiency of CAT Caterpillar gas-fired internal combustion generator sets is about 33-41%, and the efficiency of combined heat, power and cooling can reach more than 80%.

  • Low requirements for gas source: The gas internal combustion generator set has low requirements on the intake pressure (medium and low pressure) and intake temperature of the gas source, and has a wide range of calorific value.

  • Wide range of power used: Caterpillar gas internal combustion generator sets have a power range of 80 to 3480KW, which can operate as a single unit or in parallel with multiple units, grid-connected operation, and flexible station construction.

  • Wide range of adaptation to ambient temperature and altitude. At an ambient temperature of 40 degrees Celsius and an altitude of 500 meters, the rated power of the Caterpillar gas-fired internal combustion generator set is not compromised, and it can output 100%.

Technical Specifications

Basic Introduction of  CAT 3512B-1625 Diesel Generator Set

Genset Model: 3512B-1625
Prime Power: 1500 kVA
Genset Frequency: 50 Hz
Engine Model: 3512
Rated Power: 1500 r/min @ 1200 kW
Alternator Brand: N/A
Alternator Model: N/A
Genset Dimension: N/A
Wet Weight: N/A
Lead Time: 15-30 Working Days
Payment Terms: T/T ,L/C

Engine Model

Standby

Prime

Aspiration

Fuel System

3512-1250 1250 kVA / 1000 ekW 1150 kVA / 920 ekW Turbocharged & Water-Air Intercooler Mechanical Single Unit pump
3512-1400 1400 kVA / 1120 ekW 1275 kVA / 1020 ekW Turbocharged & Water-Air Intercooler Mechanical Single Unit pump
3512B-1625 1625 kVA / 1300 ekW 1500 kVA / 1200 ekW Turbocharged & Water-Air Intercooler Mechanical Single Unit pump
3512B-1750 1750 kVA / 1400 ekW 1600 kVA / 1280 ekW Turbocharged & Water-Air Intercooler Mechanical Single Unit pump
——END——

General Information of CAT 3512B-1625 Diesel Generator Set

Engine Model 3512B-1625 Displacement 51.8 L / 3161.03 in³
Bore 170 mm / 6.69 in Stroke 190 mm / 7.48 in
Compress Ratio 14.0:1 Fuel System Mechanical Single Unit pump
Aspiration TA Governor Type ADEM™ A3
Standby 1625 kVA / 1300 ekW Prime 1500 kVA / 1200 ekW
Mission Critical 1625 kVA / 1300 ekW Continuous 1320 kVA / 1056 ekW
Length 5404 mm / 212.8 in Width 2286  mm / 90.0 in
Height 2411 mm / 94.9 in Dry Weight 11621 kg / 25620 Ib
Emissions Performance Low Fuel Consumption or Low Emissions Frequency 50 Hz
——END——

Package Performance of CAT 3512B-1625 Diesel Generator Set

Standby Mission Critical Prime Continuous
Performance Frequency — Hz 50 50 50 50
Gen Set Power Rating with Fannt — ekW 1300 1300 1200 1056
Gen Set Power Rating with Fan @0.8 Power Factor — kVA 1625 1625 1500 1320
Emissions Low Fuel Low Fuel Low Fuel Low Fuel
Performance Number N/A N/A DM8048-01 DM8033-01
Fuel Consumption 100% Load With Fan — L/hr  ( gal/hr ) N/A N/A 308.8 / 81.6 271.7 / 71.8
75% Load With Fan — L/hr  ( gal/hr ) N/A N/A 232.5 / 61.4 206.3 / 54.5
50% Load With Fan — L/hr  ( gal/hr ) N/A N/A 162.3 / 42.9 146.7 / 38.8
25% Load With Fan — L/hr  ( gal/hr ) N/A N/A 97.4 / 25.7 89.7 / 23.7
Cooling System Radiator Air Flow Restriction — kPa  ( in.water ) 0.12 / 0.48 0.12 / 0.48 0.12 / 0.48 0.12 / 0.48
Radiator Air Flow — m³/min  ( cfm ) 1734 / 61235 1734 / 61235 1734 / 61235 1734 / 61235
Engine Coolant Capacity — L  ( gal ) 156.8 / 41.4 156.8 / 41.4 156.8 / 41.4 156.8 / 41.4
Radiator Coolant Capacity — L  ( gal ) 146 / 38.0 146 / 38.0 146 / 38.0 146 / 38.0
Total Coolant Capacity — L  ( gal ) 302.8 / 79.4 302.8 / 79.4 302.8 / 79.4 302.8 / 79.4
Inlet Air Combustion Air Inlet Flow Rate — m³/min ( cfm ) N/A N/A 108.3 / 3824.1 98.1 / 3464.0
Exhaust System Exhaust Stack Gas Temperature — °C  ( °F ) N/A N/A 392.4 / 738.3 388 / 730.4
Exhaust Gas Flow Rate — m³/min  ( cfm ) N/A N/A 253.2 / 8940.6 226.3 / 7990.8
Exhaust System Backpressure  — kPa  ( in. Water ) N/A N/A 6.7 / 26.9 6.7 / 26.9
Heat Rejection Heat Rejection To Jacket Water — kW  ( Btu/min ) N/A N/A 480 / 27297 437 / 24852
Heat Rejection To Exhaust (Total) — kW  ( Btu/min ) N/A N/A 1030 / 58574 914 / 51978
Heat Rejection To Aftercooler — kW  ( Btu/min ) N/A N/A 331 / 18823 266 / 15127
Heat Rejection To Atmosphere From Engine — kW  ( Btu/min ) N/A N/A 111 / 6312 106 / 6028
Heat Rejection From Alternator — kW  ( Btu/min ) N/A N/A 51 / 2917 49 / 2764
Emissions* (Nominal) NOX — mg/Nm³  ( g/hp-h ) N/A N/A 3243.7 / 6.58 3312.8 / 6.72
CO — mg/Nm³  ( g/hp-h ) N/A N/A 698.4 / 1.42 717.9 / 1.46
HC — mg/Nm³  ( g/hp-h ) N/A N/A 69.9 / 0.14 82.8 / 0.17
PM — mg/Nm³  ( g/hp-h ) N/A N/A 32 / 0.06 33.4 / 0.07
Emissions* (Potential Site Variation) NOX — mg/Nm³  ( g/hp-h ) N/A N/A 3892.5 / 7.90 3975.3 / 8.07
CO — mg/Nm³  ( g/hp-h ) N/A N/A 1257.1 / 2.25 1292.2 / 2.62
HC — mg/Nm³  ( g/hp-h ) N/A N/A 93 / 0.19 110.1 / 0.22
PM — mg/Nm³  ( g/hp-h ) N/A N/A 44.8 / 0.09 46.8 / 0.09
——END——

Ratings Definitions of CAT 3512-1625 Diesel Generator Set

Standby 1. Output Available With Varying Load For The Duration Of The Interruption Of The Normal Source Power. Average Power Outputis 70% Of The Standby Power Rating Typical Operation Is 200 Hours Per Year, With Maximum Expected Usage Of 500 Hours Per Year Prime 1. Output Available With Varying Load For An Unlimited Time. Average Power Output Is 70% Of The Prime Power Rating. Typical Peak Demand Is 100% Of Prime Rated Ekw With 10% Overload Capability For Emergency Use For A Maximum Of 1 Hour In 12. Overload Operation Cannot Exceed 25 Hours Per Year
Fuel Rates 1. Fuel Rates Are Based On Fuel Oil Of 35º Api [16°C (60ºf)] Gravity Having An Lhv Of 42,780 Kj/Kg (18,390 Btu/Lb) When Used At 29ºc (85ºf) And Weighing 838.9 G/Liter (7.001 Lbs/U.S. Gal.) Applicable Codes and Standards 1. As 1359, Csa C22.2 No. 100-04, Ul 142, Ul 489,Ul 869, Ul 2200, Nfpa 37, Nfpa 70, Nfpa 99, Nfpa 110, Ibc, Iec 60034-1, Iso 3046, Iso 8528, Nema Mg1-22, Nema Mg1-33, 2014/35/Eu, 2006/42/Ec, 2014/30/Eu
Data Center Applications 1. Lso 8528-1 Data Center Power (Dcp) Compliant Per Dcp Application Of Cat Diesel Generator Set Prime Power Rating
2. All Ratings Tier Iii/Tier Iv Compliant Per Uptime Institute Requirements
3. All Ratings Ansi/Tia-942 Compliant For Rated-1 Through Rated-4 Data Centers
——END——

Optional Equipment of CAT 3512-1625 Diesel Generator Set

Engine Air Cleaner Power Termination Type Alternator Output Voltage
1. Single Element 1. Bus Bar 1. 380 V
2. Dual Element 2. Circuit Breaker 2. 400 V
3. Heavy Duty 3. 1250 A 3. 415 V
Muffler 4. 1600 A Temperature Rise(Over 40°C Ambient)
1. Industrial Grade (10 Db) 5. 2500 A 1. 125 °C
Starting 6. 3-Pole 2. 105 °C
1. Standard Batteries 7. Iec 3. 3.08 °C
2. Oversized Batteries 8. Manually Operated Winding Type
3.  Heavy Duty Electric Starter(S) 9. Electrically Operated 1. Random Wound
4. Dual Electric Starter(S) Trip Unit Excitation
5. Jacket Water Heater 1. Lsi 1. Self Excited
6. N/A 2. N/A 2. Permanent Magnet (Pm)
Control System Controller Extended Service Options Terms Ancillary Equipment 1. Automatic Transfer Switch
1. Emcp 4.2B 1. 2 Year (Prime) 2. Uninterruptible Power Supply
2. Emcp 4.3  2. 3 Year 3. Paralleling Switchgear
3. Emcp 4.4 3.  5 Year 4. Paralleling Controls
Attachments  4. 10 Year Connectivity
1. Local Annunciator Module Coverage 1. Ethernet
2. Remote Annunciator Module 1. Silver 2. Cellular
3. Expansion I/O Module 2. Gold 3. Satellite
4. Remote Monitoring Software 3.  Platinum 4. N/A
5. N/A 4. Platinum Plus 5. N/A
Fuel Tank 1. 317 Gal (1200 L) Charging  1. Battery Charger – 5A Certifications 1. Eurasian Conformity (EAC)
——END——

Standard Features of CAT 3512-1625 Diesel Generator Set

Generator Set Package 1. Designed And Optimized For Low Fuel Consumption Alternators 1. Superior Motor Starting Capability Minimizes Need For Oversizing Generator
2. Reliable Performance Proven In Thousands Of Applications Worldwide 2. Designed To Match Performance And Output Characteristics Of Cat Diesel Engines
Generator Set Package 1. Accepts 100% Block Load In One Step And Meets Nfpa 110 Loading Requirements EMCP 4 Control Panels 1. User-Friendly Interface And Navigation
2. Conforms To Iso 8528-5 G3 Load Acceptance Requirements 2. Scalable System To Meet A Wide Range Of Installation Requirements
3. Reliability Verified Through Torsional Vibration, Fuel Consumption, Oil Consumption, Transient,Performance, And Endurance Testing 3. Expansion Modules And Site Specific Programming For Specific Customer Requirements
Cooling System 1. Cooling Systems Available To Operate In Ambient Temperatures Up To 50°C (122°F) Worldwide Product Support 1. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries
2. Tested To Ensure Proper Generator Set Cooling 2. Your Local Cat Dealer Provides Extensivepost-Sale Support, Including Maintenance And Repair Agreements
Warranty 1. 24 Months/1000-Hour Warranty For Standby And Mission Critical Ratings Financing 1. Caterpillar Offers An Array Of Financial Products To Help You Succeed Through Financial Service excel7935731lence
2. 12 Months/Unlimited Hour Warranty For Prime And Continuous Ratings 2. Options Include Loans, Finance Lease,Operating Lease, Working Capital, And Revolving Line Of Credit
3. Extended Service Protection Is Available To Provide Extended Coverage Options 3. Contact Your Local Cat Dealer For Availability In Your Region
——END——

Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

WhatsApp Online logo

Sales Team


Marine Sales - Mrs. Gazit Wong WhatApp-Icon

Train Sales - Mrs. Gazit Wong WhatApp-Icon

Automotive Sales - Mrs. Shelly LiuWhatApp-Icon

Industrial Sales - Mrs. Kitty Chen WhatApp-Icon

Generator Sales - Mrs. Erica WhatApp-Icon

Pump Sales - Mrs. Ryen WhatApp-Icon

Spare Parts - Mrs. Nora Chen WhatApp-Icon

Sales Manager - Mrs. Wendy Fu

Ventas españolas - Victoria

Sales Director - Mr. Jasper Lee       WhatApp-Icon

Contact EMAC Now!

Subscribe To Our Newsletter

Subscribe To Our Newsletter

Subscribe to get the latest updates from cat-generator.com/

Welcome on board, we will keep you updated with latest news and business activities!

Pin It on Pinterest