Select Page

Caterpillar 3412-900 Diesel Generator Set

CAT 3412-900 Diesel Generator Sets is a V-4-Cylinders 27.02 Liter (1648.86 in) Displacement Engine with 152.4 mm (6.0 in.) Bore and 152.4 mm (6.0 in.) Stroke.

Equipped with Dual Caterpillar® A3 Electronic Control Unit (ECU) LH with Electronic Unit Injector Fuel System Rigid Wiring Harness and ADEM™ A5 Governor.The Prime Power for 50 Hz Generator Set (1500 RPM) of CAT 3412-900 Diesel Generator Sets is 810.0 kVA (648.0 kW) and a Standby Power of 900.0 kVA (720.0 kW).

CAT 3412-900 Diesel Genset Powered by CAT Diesel Engine with EMCP 4 Control Panel, Diesel Genset with Turbochargered & Intercooled.

CAT Diesel Generator Sets Meet Tier III/Tier IV Emission Standards. As Part of EMAC, CAT Diesel Generator Sets Also Provide 50 Hz and 60 Hz Diesel Generator Sets. Engine Brands Include Cummins, Deutz, Perkins, MTU, WeiChai and CAT.

Our Diesel Generator Set Series Includes High Power Medium and High Voltage Generator Sets and High Power Low Voltage Generator Sets. The Engine Provides Electronically Controlled and Mechanical Fuel Injection Systems for Customers to Choose. In Addition to Generating Diesel Generator Sets, We Can Also Supply Marine Diesel, Oil, Gas, Marine Generator Sets.

We Provide Full Life Cycle Services for All Customers, From Design to Power System Supply, From Installation to Commissioning, From After-Sales Service Training to Spare Parts Supply, From Troubleshooting to Overhaul Technical Support.

Advantages of Caterpillar 3412-900 Diesel GenSet

  • High power generation efficiency: The power generation efficiency of CAT Caterpillar gas-fired internal combustion generator sets is about 33-41%, and the efficiency of combined heat, power and cooling can reach more than 80%.

  • Low requirements for gas source: The gas internal combustion generator set has low requirements on the intake pressure (medium and low pressure) and intake temperature of the gas source, and has a wide range of calorific value.

  • Wide range of power used: Caterpillar gas internal combustion generator sets have a power range of 80 to 3480KW, which can operate as a single unit or in parallel with multiple units, grid-connected operation, and flexible station construction.

  • Wide range of adaptation to ambient temperature and altitude. At an ambient temperature of 40 degrees Celsius and an altitude of 500 meters, the rated power of the Caterpillar gas-fired internal combustion generator set is not compromised, and it can output 100%.

Technical Specifications

Basic Introduction of CAT 3412-900 Diesel Generator Set

Genset Model: 3412-900
Prime Power: 810 kVA
Genset Frequency: 50 Hz
Engine Model: 3412
Rated Power: 1500 r/min @ 810 kW
Alternator Brand: N/A
Alternator Model: N/A
Genset Dimension: N/A
Wet Weight: N/A
Lead Time: 15-30 Working Days
Payment Terms: T/T ,L/C

Engine Model

Standby

Prime

Aspiration

Fuel System

3412-800 800 kVA / 640 ekW 725 kVa / 850 ekW Turbochargered & Intercooled Pump and Lines
3412-900 900 kVA / 720 ekW 810 kVa / 648 ekW Turbochargered & Intercooled Pump and Lines
——END——

General Information of CAT 3412-900 Diesel Generator Set

Engine Model 3412-900 Displacement 27.02 L / 1648.86 in
Bore 137.2 mm / 5.4 in Stroke 152.4 mm / 6 in
Compress Ratio 13.0:1 Fuel System Pump and Lines
Aspiration TA Governor Type ADEM™ A5
Standby 900 kVA / 720 ekW Prime 810 kVA / 648 ekW
Length 4125 mm / 162.4 in Width 1705 mm / 67.1 in
Height 1906 mm / 75 in Dry Weight 5679 kg / 12521 Ib
Emissions Performance Optimized for Low Fuel Consumption Frequency 50 Hz
——END——

Package Performance of Cat 3412-900 Diesel Generator Sets

Standby Prime
Performance Frequency 50 Hz 50 Hz
Gen Set Power Rating with Fan 720 ekW 648 ekW
Gen Set Power Rating with Fan @0.8 Power Factor 900 kVA 810 kVA
Emissions Low Fuel Low Fuel
Performance Number EM1164-00  EM1165-00
Fuel Consumption 100% Load with Fan 191.7 L/hr / 50.6 gal/hr 171.1 L/hr / 45.3 gal/hr
75% Load with Fan 143.8 L/hr / 38.0 gal/hr 130.2 L/hr / 34.4 gal/hr
50% Load with Fan 99.5 L/hr / 26.3 gal/hr 90.7 L/hr / 23.9 gal/hr
25% Load with Fan 57.0 L/hr / 15.0 gal/hr 52.4 L/hr / 13.8 gal/hr
Cooling System Radiator Air Flow Restriction 0.12 kPa / 0.48 in.water 0.12 kPa / 0.48 in.water
Radiator Air Flow 815 m³/min / 28781 cfm 815 m³/min / 28781 cfm
Engine Coolant Capacity 58.6 L / 15.5 gal 58.6 L / 15.5 gal
Radiator Coolant Capacity 90.0 L / 23.8 gal 90.0 L / 23.8 gal
Total Coolant Capacity 148.8 L / 39.3 gal 148.8 L / 39.3 gal
Inlet Air Combustion Air Inlet Flow Rate 54.6 m³/min  / 1928.7 cfm 48.8 m³/min  / 1721.4 cfm
Exhaust System Exhaust Stack Gas Temperature 544.2 °C / 1011.5 °F 539.4 °C / 1002.9 °F
Exhaust Gas Flow Rate 156.4 m³/min / 5521.9 cfm 139.1 m³/min / 4913.4 cfm
Exhaust System Backpressure 6.7 kPa / 27.0 in. Water 6.7 kPa / 27.0 in. Water
Heat Rejection Heat Rejection to Jacket Water 431 kW / 24527 Btu/min 385 kW / 21921 Btu/min
Heat Rejection to Exhaust (Total) 701 kW / 39846 Btu/min 636 kW / 36184 Btu/min
Heat Rejection to Aftercooler 115 kW / 6518 Btu/min 85 kW / 4860 Btu/min
Heat Rejection to Atmosphere From Engine 120 kW / 6801 Btu/min 108 kW /  6122 Btu/min
Heat Rejection From Alternator 28 kW / 1575 Btu/min 24 kW / 1376 Btu/min
Emissions* (Nominal) NOX 3167.8 mg/Nm³  / 6.05 g/hp-h 3167.8 mg/Nm³  / 6.06 g/hp-h
CO 443.3 mg/Nm³  / 0.97 g/hp-h 193.7 mg/Nm³  / 0.41 g/hp-h
HC 248.1 mg/Nm³  / 0.57 g/hp-h 122.3 mg/Nm³  / 0.26 g/hp-h
PM 51.5 mg/Nm³  / 0.13 g/hp-h 45.9 mg/Nm³  / 0.10 g/hp-h
Emissions* (Potential Site Variation) NOX 3833.0 mg/Nm³ / 7.33 g/hp-h 3596.7 mg/Nm³ / 7.52 g/hp-h
CO 828.9 mg/Nm³ / 1.82 g/hp-h 362.2 mg/Nm³ / 0.76 g/hp-h
HC 468.9 mg/Nm³ / 1.07 g/hp-h 231.1 mg/Nm³ / 0.48 g/hp-h
PM 100.5 mg/Nm³ / 0.26 g/hp-h 89.5 mg/Nm³ / 0.19 g/hp-h
——END——

Ratings Definitions of CAT 3412-900 Diesel Generator Set

Standby 1. Output Available With Varying Load For The Duration Of The Interruption Of The Normal Source Power. Average Power Outputis 70% Of The Standby Power Rating Typical Operation Is 200 Hours Per Year, With Maximum Expected Usage Of 500 Hours Per Year Prime 1. Output Available With Varying Load For An Unlimited Time. Average Power Output Is 70% Of The Prime Power Rating. Typical Peak Demand Is 100% Of Prime Rated Ekw With 10% Overload Capability For Emergency Use For A Maximum Of 1 Hour In 12. Overload Operation Cannot Exceed 25 Hours Per Year
Fuel Rates 1. Fuel Rates Are Based On Fuel Oil Of 35º Api [16°C (60ºf)] Gravity Having An Lhv Of 42,780 Kj/Kg (18,390 Btu/Lb) When Used At 29ºc (85ºf) And Weighing 838.9 G/Liter (7.001 Lbs/U.S. Gal.) Applicable Codes and Standards 1. As 1359, Csa C22.2 No. 100-04, Ul 142, Ul 489,Ul 869, Ul 2200, Nfpa 37, Nfpa 70, Nfpa 99, Nfpa 110, Ibc, Iec 60034-1, Iso 3046, Iso 8528, Nema Mg1-22, Nema Mg1-33, 2014/35/Eu, 2006/42/Ec, 2014/30/Eu
Data Center Applications 1. Lso 8528-1 Data Center Power (Dcp) Compliant Per Dcp Application Of Cat Diesel Generator Set Prime Power Rating
2. All Ratings Tier Iii/Tier Iv Compliant Per Uptime Institute Requirements
3. All Ratings Ansi/Tia-942 Compliant For Rated-1 Through Rated-4 Data Centers
——END——

Optional Equipment of CAT 3412-900 Diesel Generator Set

Engine Air Cleaner Power Termination Type Alternator Output Voltage
1. Single Element 1. Bus Bar 1. 380 V
2. Dual Element 2. Circuit Breaker 2. 400 V
3. Heavy Duty 3. 1250 A 3. 415 V
Muffler 4. 1600 A Temperature Rise(Over 40°C Ambient)
1. Industrial Grade (10 Db) 5. 2500 A 1. 125 °C
Starting 6. 3-Pole 2. 105 °C
1. Standard Batteries 7. Iec 3. 3.08 °C
2. Oversized Batteries 8. Manually Operated Winding Type
3.  Heavy Duty Electric Starter(S) 9. Electrically Operated 1. Random Wound
4. Dual Electric Starter(S) Trip Unit Excitation
5. Jacket Water Heater 1. Lsi 1. Self Excited
6. N/A 2. N/A 2. Permanent Magnet (Pm)
Control System Controller Extended Service Options Terms Ancillary Equipment 1. Automatic Transfer Switch
1. Emcp 4.2B 1. 2 Year (Prime) 2. Uninterruptible Power Supply
2. Emcp 4.3  2. 3 Year 3. Paralleling Switchgear
3. Emcp 4.4 3.  5 Year 4. Paralleling Controls
Attachments  4. 10 Year Connectivity
1. Local Annunciator Module Coverage 1. Ethernet
2. Remote Annunciator Module 1. Silver 2. Cellular
3. Expansion I/O Module 2. Gold 3. Satellite
4. Remote Monitoring Software 3.  Platinum 4. N/A
5. N/A 4. Platinum Plus 5. N/A
Fuel Tank 1. 317 Gal (1200 L) Charging  1. Battery Charger – 5A Certifications 1. Eurasian Conformity (EAC)
——END——

Standard Features of CAT 3412-900 Diesel Generator Set

Generator Set Package 1. Designed And Optimized For Low Fuel Consumption Alternators 1. Superior Motor Starting Capability Minimizes Need For Oversizing Generator
2. Reliable Performance Proven In Thousands Of Applications Worldwide 2. Designed To Match Performance And Output Characteristics Of Cat Diesel Engines
Generator Set Package 1. Accepts 100% Block Load In One Step And Meets Nfpa 110 Loading Requirements EMCP 4 Control Panels 1. User-Friendly Interface And Navigation
2. Conforms To Iso 8528-5 G3 Load Acceptance Requirements 2. Scalable System To Meet A Wide Range Of Installation Requirements
3. Reliability Verified Through Torsional Vibration, Fuel Consumption, Oil Consumption, Transient,Performance, And Endurance Testing 3. Expansion Modules And Site Specific Programming For Specific Customer Requirements
Cooling System 1. Cooling Systems Available To Operate In Ambient Temperatures Up To 50°C (122°F) Worldwide Product Support 1. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries
2. Tested To Ensure Proper Generator Set Cooling 2. Your Local Cat Dealer Provides Extensivepost-Sale Support, Including Maintenance And Repair Agreements
Warranty 1. 24 Months/1000-Hour Warranty For Standby And Mission Critical Ratings Financing 1. Caterpillar Offers An Array Of Financial Products To Help You Succeed Through Financial Service excel7935731lence
2. 12 Months/Unlimited Hour Warranty For Prime And Continuous Ratings 2. Options Include Loans, Finance Lease,Operating Lease, Working Capital, And Revolving Line Of Credit
3. Extended Service Protection Is Available To Provide Extended Coverage Options 3. Contact Your Local Cat Dealer For Availability In Your Region
——END——

Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

The picture of Sale Manual showing the accessories and scopes of supply.

Engine Sale Manual

The picture of Installation Drawing showing the accessories and scopes of supply.

Installation Drawing

The picture of Installation Manual showing the accessories and scopes of supply.

Installation Manual

The picture of Operation Manual showing the accessories and scopes of supply.

Operation Manual

The picture of Engine Parts Catalogue showing the accessories and scopes of supply.

Parts Catalogue

The picture of Test Report and Certifcate showing the accessories and scopes of supply.

Report & Certifcate

WhatsApp Online logo

Sales Team


Marine Sales - Mrs. Gazit Wong WhatApp-Icon

Train Sales - Mrs. Gazit Wong WhatApp-Icon

Automotive Sales - Mrs. Shelly LiuWhatApp-Icon

Industrial Sales - Mrs. Kitty Chen WhatApp-Icon

Generator Sales - Mrs. Erica WhatApp-Icon

Pump Sales - Mrs. Ryen WhatApp-Icon

Spare Parts - Mrs. Nora Chen WhatApp-Icon

Sales Manager - Mrs. Wendy Fu

Ventas españolas - Victoria

Sales Director - Mr. Jasper Lee       WhatApp-Icon

Contact EMAC Now!

Subscribe To Our Newsletter

Subscribe To Our Newsletter

Subscribe to get the latest updates from cat-generator.com/

Welcome on board, we will keep you updated with latest news and business activities!

Pin It on Pinterest