Caterpillar 3412-800 Diesel Generator Set

CAT 3412-800 Diesel Generator Sets is a V-4-Cylinders 27.02 Liter (1648.86 in) Displacement Engine with 152.4 mm (6 in.) Bore and 152.4 mm (6 in.) Stroke.

Equipped with Dual Caterpillar® A3 Electronic Control Unit (ECU) LH with Electronic Unit Injector Fuel System Rigid Wiring Harness and ADEM™ A5 Governor.The Prime Power for 50 Hz Generator Set (1500 RPM) of CAT 3412-800 Diesel Generator Sets is 725 kVA (580.0 kW) and a Standby Power of 800.0 kVA (640 kW).

CAT 3412-800 Diesel Genset Powered by CAT Diesel Engine with EMCP 4 Control Panel, Diesel Genset with Turbochargered & Intercooled.

CAT Diesel Generator Sets Meet Tier III/Tier IV Emission Standards. As Part of EMAC, CAT Diesel Generator Sets Also Provide 50 Hz and 60 Hz Diesel Generator Sets. Engine Brands Include Cummins, Deutz, Perkins, MTU, WeiChai and CAT.

Our Diesel Generator Set Series Includes High Power Medium and High Voltage Generator Sets and High Power Low Voltage Generator Sets. The Engine Provides Electronically Controlled and Mechanical Fuel Injection Systems for Customers to Choose. In Addition to Generating Diesel Generator Sets, We Can Also Supply Marine Diesel, Oil, Gas, Marine Generator Sets.

We Provide Full Life Cycle Services for All Customers, From Design to Power System Supply, From Installation to Commissioning, From After-Sales Service Training to Spare Parts Supply, From Troubleshooting to Overhaul Technical Support.

Advantages of Caterpillar 3412-800 Diesel GenSet

  • High power generation efficiency: The power generation efficiency of CAT Caterpillar gas-fired internal combustion generator sets is about 33-41%, and the efficiency of combined heat, power and cooling can reach more than 80%.

  • Low requirements for gas source: The gas internal combustion generator set has low requirements on the intake pressure (medium and low pressure) and intake temperature of the gas source, and has a wide range of calorific value.

  • Wide range of power used: Caterpillar gas internal combustion generator sets have a power range of 80 to 3480KW, which can operate as a single unit or in parallel with multiple units, grid-connected operation, and flexible station construction.

  • Wide range of adaptation to ambient temperature and altitude. At an ambient temperature of 40 degrees Celsius and an altitude of 500 meters, the rated power of the Caterpillar gas-fired internal combustion generator set is not compromised, and it can output 100%.

Technical Specifications

Basic Introduction of CAT 3412-800 Diesel Generator Set

Genset Model: 3412-800
Prime Power: 725 kVA
Genset Frequency: 50 Hz
Engine Model: 3412
Rated Power: 1500 r/min @ 850 kW
Alternator Brand: N/A
Alternator Model: N/A
Genset Dimension: N/A
Wet Weight: N/A
Lead Time: 15-30 Working Days
Payment Terms: T/T ,L/C

Engine Model

Standby

Prime

Aspiration

Fuel System

3412-800 800 kVA / 640 ekW 725 kVa / 850 ekW Turbochargered & Intercooled Pump and Lines
3412-900 900 kVA / 720 ekW 810 kVa / 648 ekW Turbochargered & Intercooled Pump and Lines
——END——

General Information of CAT 3412-800 Diesel Generator Set

Engine Model 3412-800 Displacement 27.02 L / 1648.86 in
Bore 137.2 mm / 5.4 in Stroke 152.4 mm / 6 in
Compress Ratio 13.0:1 Fuel System Pump And Lines
Aspiration Turbocharged-Aftercooled Governor Type ADEM™ A5
Standby 800 kVA / 640 ekW Prime 725 kVA / 580 ekW
Length 4125 mm / 162.4 in Width 1705 mm / 67.1 in
Height 1906 mm / 75 in Dry Weight 5461 kg / 12039 Ib
Emissions Performance Optimized for Low Fuel Consumption Frequency 50 Hz
——END——

Package Performance of CAT 3412-800 Diesel Generator Set

Standby Prime
Performance Frequency — Hz 50 50
Gen Set Power Rating with Fannt — ekW 640 580
Gen Set Power Rating with Fan @ 0.8 Power Factor — kVA 800 725
Emissions Low Fuel Low Fuel
Performance Number EM1166-01  EM1167-01
Fuel Consumption 100% Load with Fan — L/hr  ( gal/hr ) 169.1  / 44.7 153.7 / 40.6
75% Load with Fan — L/hr  ( gal/hr ) 128.9 / 34.1 117.5 / 31.0
50% Load with Fan — L/hr  ( gal/hr ) 90.0 / 23.8 82.5 / 21.8
25% Load with Fan — L/hr  ( gal/hr ) 52.1 / 23.8 48.2 / 12.7
Cooling System Radiator Air Flow Restriction — kPa  ( in.water ) 0.12 / 0.48 0.12 / 0.48
Radiator Air Flow — m³/min  ( cfm ) 815 / 28781 815 / 28781
Engine Coolant Capacity — L  ( gal ) 58.6 / 15.5 58.6 / 15.5
Radiator Coolant Capacity — L  ( gal ) 90.0 /  23.8 90.0 / 23.8
Total Coolant Capacity — L  ( gal ) 148.8 / 39.3 148.8 / 39.3
Inlet Air Combustion Air Inlet Flow Rate — m³/min ( cfm ) 48.1  / 1698.5 44.2 / 1560.8
Exhaust System Exhaust Stack Gas Temperature — °C  ( °F ) 538.7 / 1001.7 534.0 / 993.2
Exhaust Gas Flow Rate — m³/min  ( cfm ) 137.2 /  4844.7 125.4 / 4428.1
Exhaust System Backpressure  — kPa  ( in. Water ) 6.7 / 27.0 6.7 / 27.0
Heat Rejection Heat Rejection to Jacket Water — kW  ( Btu/min ) 381 / 21667 347 / 19734
Heat Rejection to Exhaust (Total) — kW  ( Btu/min ) 628 / 35714 571 /  32473
Heat Rejection to Aftercooler — kW  ( Btu/min ) 83 /  4703 66 / 3776
Heat Rejection to Atmosphere From Engine — kW  ( Btu/min ) 105 / 5971 95 / 5402
Heat Rejection From Alternator — kW  ( Btu/min ) 25 / 1439 22 / 1268
Emissions* (Nominal) NOX — mg/Nm³  ( g/hp-h ) 2969.2  / 6.21 2932.1  / 6..14
CO — mg/Nm³  ( g/hp-h ) 181.6 / 0.38 171.7  / 0.36
HC — mg/Nm³  ( g/hp-h ) 120.1 / 0.25 102.6  / 0.21
PM — mg/Nm³  ( g/hp-h ) 45.1 / 0.09 45.0  / 0.09
Emissions* (Potential Site Variation) NOX — mg/Nm³  ( g/hp-h ) 3592.7 / 7.51 3547.8 /  7.43
CO — mg/Nm³  ( g/hp-h ) 339.6 / 0.71 321.1 /  0.67
HC — mg/Nm³  ( g/hp-h ) 227.0 / 0.48 193.9 / 0.41
PM — mg/Nm³  ( g/hp-h ) 87.9 / 0.18 87.7 / 0.18
——END——

Ratings Definitions of CAT 3412-800 Diesel Generator Set

Standby 1. Output Available With Varying Load For The Duration Of The Interruption Of The Normal Source Power. Average Power Outputis 70% Of The Standby Power Rating Typical Operation Is 200 Hours Per Year, With Maximum Expected Usage Of 500 Hours Per Year Prime 1. Output Available With Varying Load For An Unlimited Time. Average Power Output Is 70% Of The Prime Power Rating. Typical Peak Demand Is 100% Of Prime Rated Ekw With 10% Overload Capability For Emergency Use For A Maximum Of 1 Hour In 12. Overload Operation Cannot Exceed 25 Hours Per Year
Fuel Rates 1. Fuel Rates Are Based On Fuel Oil Of 35º Api [16°C (60ºf)] Gravity Having An Lhv Of 42,780 Kj/Kg (18,390 Btu/Lb) When Used At 29ºc (85ºf) And Weighing 838.9 G/Liter (7.001 Lbs/U.S. Gal.) Applicable Codes and Standards 1. As 1359, Csa C22.2 No. 100-04, Ul 142, Ul 489,Ul 869, Ul 2200, Nfpa 37, Nfpa 70, Nfpa 99, Nfpa 110, Ibc, Iec 60034-1, Iso 3046, Iso 8528, Nema Mg1-22, Nema Mg1-33, 2014/35/Eu, 2006/42/Ec, 2014/30/Eu
Data Center Applications 1. Lso 8528-1 Data Center Power (Dcp) Compliant Per Dcp Application Of Cat Diesel Generator Set Prime Power Rating
2. All Ratings Tier Iii/Tier Iv Compliant Per Uptime Institute Requirements
3. All Ratings Ansi/Tia-942 Compliant For Rated-1 Through Rated-4 Data Centers
——END——

Optional Equipment of CAT 3412-800 Diesel Generator Set

Engine Air Cleaner Power Termination Type Alternator Output Voltage
1. Single Element 1. Bus Bar 1. 380 V
2. Dual Element 2. Circuit Breaker 2. 400 V
3. Heavy Duty 3. 1250 A 3. 415 V
Muffler 4. 1600 A Temperature Rise(Over 40°C Ambient)
1. Industrial Grade (10 Db) 5. 2500 A 1. 125 °C
Starting 6. 3-Pole 2. 105 °C
1. Standard Batteries 7. Iec 3. 3.08 °C
2. Oversized Batteries 8. Manually Operated Winding Type
3.  Heavy Duty Electric Starter(S) 9. Electrically Operated 1. Random Wound
4. Dual Electric Starter(S) Trip Unit Excitation
5. Jacket Water Heater 1. Lsi 1. Self Excited
6. N/A 2. N/A 2. Permanent Magnet (Pm)
Control System Controller Extended Service Options Terms Ancillary Equipment 1. Automatic Transfer Switch
1. Emcp 4.2B 1. 2 Year (Prime) 2. Uninterruptible Power Supply
2. Emcp 4.3  2. 3 Year 3. Paralleling Switchgear
3. Emcp 4.4 3.  5 Year 4. Paralleling Controls
Attachments  4. 10 Year Connectivity
1. Local Annunciator Module Coverage 1. Ethernet
2. Remote Annunciator Module 1. Silver 2. Cellular
3. Expansion I/O Module 2. Gold 3. Satellite
4. Remote Monitoring Software 3.  Platinum 4. N/A
5. N/A 4. Platinum Plus 5. N/A
Fuel Tank 1. 317 Gal (1200 L) Charging  1. Battery Charger – 5A Certifications 1. Eurasian Conformity (EAC)
——END——

Standard Features of CAT 3412-800 Diesel Generator Set

Generator Set Package 1. Designed And Optimized For Low Fuel Consumption Alternators 1. Superior Motor Starting Capability Minimizes Need For Oversizing Generator
2. Reliable Performance Proven In Thousands Of Applications Worldwide 2. Designed To Match Performance And Output Characteristics Of Cat Diesel Engines
Generator Set Package 1. Accepts 100% Block Load In One Step And Meets Nfpa 110 Loading Requirements EMCP 4 Control Panels 1. User-Friendly Interface And Navigation
2. Conforms To Iso 8528-5 G3 Load Acceptance Requirements 2. Scalable System To Meet A Wide Range Of Installation Requirements
3. Reliability Verified Through Torsional Vibration, Fuel Consumption, Oil Consumption, Transient,Performance, And Endurance Testing 3. Expansion Modules And Site Specific Programming For Specific Customer Requirements
Cooling System 1. Cooling Systems Available To Operate In Ambient Temperatures Up To 50°C (122°F) Worldwide Product Support 1. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries
2. Tested To Ensure Proper Generator Set Cooling 2. Your Local Cat Dealer Provides Extensivepost-Sale Support, Including Maintenance And Repair Agreements
Warranty 1. 24 Months/1000-Hour Warranty For Standby And Mission Critical Ratings Financing 1. Caterpillar Offers An Array Of Financial Products To Help You Succeed Through Financial Service excel7935731lence
2. 12 Months/Unlimited Hour Warranty For Prime And Continuous Ratings 2. Options Include Loans, Finance Lease,Operating Lease, Working Capital, And Revolving Line Of Credit
3. Extended Service Protection Is Available To Provide Extended Coverage Options 3. Contact Your Local Cat Dealer For Availability In Your Region
——END——

Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

The picture of Sale Manual showing the accessories and scopes of supply.

Engine Sale Manual

The picture of Installation Drawing showing the accessories and scopes of supply.

Installation Drawing

The picture of Installation Manual showing the accessories and scopes of supply.

Installation Manual

The picture of Operation Manual showing the accessories and scopes of supply.

Operation Manual

The picture of Engine Parts Catalogue showing the accessories and scopes of supply.

Parts Catalogue

The picture of Test Report and Certifcate showing the accessories and scopes of supply.

Report & Certifcate

WhatsApp Online logo

Sales Team


Marine Sales - Mrs. Gazit Wong WhatApp-Icon

Train Sales - Mrs. Gazit Wong WhatApp-Icon

Automotive Sales - Mrs. Shelly LiuWhatApp-Icon

Industrial Sales - Mrs. Kitty Chen WhatApp-Icon

Generator Sales - Mrs. Erica WhatApp-Icon

Pump Sales - Mrs. Ryen WhatApp-Icon

Spare Parts - Mrs. Nora Chen WhatApp-Icon

Sales Manager - Mrs. Wendy Fu

Ventas españolas - Victoria

Sales Director - Mr. Jasper Lee       WhatApp-Icon

Contact EMAC Now!

Subscribe To Our Newsletter

Subscribe To Our Newsletter

Subscribe to get the latest updates from cat-generator.com/

Welcome on board, we will keep you updated with latest news and business activities!

Pin It on Pinterest